Activation

Turn the knob to
.
General principle: In each menu, press the
and press
to go to the next menu.
Menu C01: Access to program and setting changes
To modify settings, press the buttons in the following sequence:
times,
3 times,
5 times.
Access to the installer and
programming limitation settings
Menu C02: Outdoor temperature for no heating
Above this temperature, the circulators are off. The boiler thermostat input
control is off and the valve is forced to close.
Authorisation to modify the outdoor
temperature for no heating
Default setting: C02=0 and the temperature set to 20°C.
or
button to modify,
5
Modification of installer
Programming limitation
settings
Allowed
No
Not allowed
No
• Programs cannot be modified
Not allowed
• The frost protection setting
cannot be changed
• For each zone,
the temperature settings
are from 5°C to the Comfort
setting
Default setting: C01=0
Changes not allowed
Changes allowed (from 15°C to 25°C)
Upon activation, the temperature is set to 20°C
OK
- 10 -
Menu C03: Setting the minimum water temperature
for network 1
This is the minimum temperature provided for a heating request from the
network.
Authorisation to modify the minimum
temperature for network 1
Default setting: C03=0 and the temperature set to 20°C.
Menu C04 : Réglage de la température d'eau maximum
du réseau 1
Changes not allowed
Authorisation to modify the maximum
Changes allowed (from network 1 minimum T° + 1°C to 90°C)
temperature of network 1
Upon activation, the temperature is set to 50°C
(to match underfloor heating requirements).
IMPORTANT: If you are using underfloor heating, the temperature
must not exceed 50°C.
When you increase the maximum temperature of network 1 from 50 to
51°C, network 1 acquires the status of a radiator network:
- zone 1 automatically goes into Comfort mode from 6am to 11pm for
each day of the week,
- the slope of zone 1 is initialised at 2.
When you decrease the maximum temperature of network 1 from 51 to
50°C, network 1 acquires the status of an underfloor heating network:
- zone 1 automatically goes into continuous Comfort mode for each day
of the week,
- the slope of zone 1 is initialised at 0.8.
Default setting: C04=0 and the temperature set to 50°C.
Changes not allowed
Changes allowed (from 20°C to 60°C)
Upon activation, the temperature is set to 20°C
OK
OK