ACCESSORIES
When high SPL is required the iLF218, dual 18 inch system, provides high output at low frequencies
down to approximately 40 Hz.
The VLF series and VERIS loudspeakers also feature DYNA-TECH overload protection circuitry to
prevent system damage.
Recommended crossover filter settings for use with these Community subwoofers are given in Table 7.
Model
HP Filter
HP Slope
HP Freq.
LP Filter
LP Slope
LP Freq.
Polarity
EQ Filter 1
Frequency
Bandwidth
Level
EQ Filter 2
Frequency
Bandwidth
Level
EQ Filter 3
Frequency
Bandwidth
Level
EQ Filter 4
Frequency
Bandwidth
Level
HP = High Pass Filter
LP = Low Pass Filter
PEQ = Parametric EQ
Filter Bandwidth is given in percent of an octave, not Q
Table 7: Recommended Crossover Filter Settings
ENTASYS
VLF208
BU
BU
24 dB/oct
48 dB/oct
200 Hz
55 Hz
‐
BU
‐
24 dB/oct
‐
200 Hz
Normal
Normal
PEQ
PEQ
350 Hz
58 Hz
0.30
0.20
‐5.0 dB
+9.0 dB
PEQ
PEQ
604 Hz
70 Hz
0.80
0.33
‐4.5 dB
+5.5 dB
PEQ
PEQ
1.2 kHz
110 Hz
0.70
1.00
‐4.0 dB
‐2.0 dB
PEQ
PEQ
5.7 kHz
248 Hz
0.40
0.33
‐2.0 dB
‐7.0 dB
Community ENTASYS Installation/Operation Manual — Page 33
VLF212
VERIS 210S VERIS 212S
BU
BU
48 dB/oct
24 dB/oct
42 Hz
60 Hz
BU
BU
24 dB/oct
24 dB/oct
200 Hz
190 Hz
Normal
Normal
PEQ
PEQ
45 Hz
70 Hz
0.19
0.33
+4.0 dB
+3.5 dB
PEQ
PEQ
62 Hz
220 Hz
0.50
0.40
‐3.0 dB
‐9.0 dB
PEQ
‐
110 Hz
‐
1.00
‐
+1.0 dB
‐
PEQ
‐
200 Hz
‐
0.33
‐
‐7.0 dB
‐
BU = Butterworth
LR = Linkwitz‐Riley
iLF218
BU
BU
24 dB/oct
24 dB/oct
45 Hz
31 Hz
BU
BU
24 dB/oct
24 dB/oct
180 Hz
185 Hz
Normal
Normal
PEQ
PEQ
80 Hz
35 Hz
0.21
0.38
‐7.0 dB
+5.0 dB
PEQ
PEQ
244 Hz
35 Hz
0.33
0.33
‐14.0 dB
+5.0 dB
‐
PEQ
‐
169 Hz
‐
0.50
‐
‐10.0 dB
‐
PEQ
‐
581 Hz
‐
0.33
‐
‐6.0 dB
Need help?