Safety Clearance - Omnik Omniksol-1k-TL User Manual

Energy-solar inverters
Table of Contents

Advertisement

User Manual V4.2
 Omnik inverter is designed for indoors and outdoors installation
 Please mount the inverter in the direction as illustrated above
 Install the inverter in the vertical direction is recommended, with a max.15 degrees
backwards.
 For the convenience of checking the LCD display and possible maintenance
activities, please install the inverter at eye level.
 Make sure the wall you selected is strong enough to handle the screws and bear the
weight of the inverter
 Ensure the device is properly fixed to the wall
 It is not recommended that the inverter is exposed to the strong sunshine, because
the excess heating might lead to power reduction
 The ambient temperature of installation site should be between -20 ° C and +60 ° C
( between -4 ° F and 140 ° F )
 Make sure the ventilation of the installation spot, not sufficient ventilation may reduce
the performance of the electronic components inside the inverter and shorten the life
of the inverter

5.3 Safety Clearance

Observe the following minimum clearances to walls, other devices or objects to guarantee
sufficient heat dissipation and enough space for pulling the electronic solar switch handle.
10 CM
10 CM
17