System Delays & Timeouts (Addr 0000-0002, 1059 & 1179); System Delays & Timeouts (Addr 0711, 0715-0717) - NAPCO Gemini GEM-P816 Programming Instructions Manual

Table of Contents

Advertisement

WI995C 2/04
SYSTE M DE LAY S & TIMEOU TS (ADDRESS 0000 TO 0002, 0711, 0715 & 1059)
ADDRESS 0000
EXIT
ENTRY
DELAY
DELAY 1
(sec.)
(sec.)
[Default = 060]
!
Select delay/timeout (0-255 sec.) from the table shown.
EXIT/ENTRY DELAYS: Apply only to zones programmed with the following options "Exit/Entry 1, Exit/Entry
2, Exit/Entry Follower". For UL Installations, the maximum exit delay is 60 seconds and the maximum entry
delay is 45 seconds. NOTE: Sensor Watch Time Options are similar to above table, except in hours.
U
D
!
Press
or
to save.
WARNING: Timers have uncertainty of +/-1 sec, so a "time" of 1 second may actually timeout IMMEDIATELY.
SYSTE M DE LAY S & TIMEOU TS (ADDRESS 0716 & 0717)
CHIME
ADDRESS 0716
TIMEOUT
(¼sec.)
[Default = 008
¼ sec. = 2 sec.]
x
!
1. Enter delay/timeout in corresponding address locations above.
Note: All entries for address 0716 are in quarter seconds (.25 seconds).
Therefore, the default of 008 results in a 2 second timeout.
U
D
!
2. Press
or
to save.
L
NAPCO Security Systems
ADDRESS 0001
ENTRY
DELAY 2
(sec.)
[Default = 030]
[Default = 030]
Maximum Program Time
Address
1179
VERSION 10 - MIN
VERSION 9A - SEC
AC Fail
Report Delay
(min.)
[Default = 060]
ADDRESS 0002
PGM2 Output
Access Cntrl
Timeout (sec.)
[Default = 0 sec. = blank (•)]
Units
Max Prog Time
VERSION 10 - 254 MIN
VERSION 9A - 254 SEC
DEFAULTS: The defaults shown on this
ADDRESS 0717
page and on the following pages are
automatically set after exiting the Easy
Menu Driven Mode.
X
GEM-P816 Programming Instructions
Page 15
ADDRESS 0711
ADDRESS 0715
ABORT
DELAY
(sec.)
[Default = 030]
ADDRESS 1059
Sensor Watch
Time
(Hrs.)
[Default = 024]
Report Cancel
ADDRESS 1179
Window
(min.)
[Default = 0 sec. = blank (•)]
See Maximum Program Time
table (at left)
!

Hide quick links: