ICON
(Primary) state, press the Z-Wave Primary
Controller Shift to Secondary icon.
5. To shift the primary controller role to a
handheld controller, follow the handheld
controller manufacturer's instructions.
When the pop-up message disappears and
controllers have shifted successfully, Z-Wave
devices can be enrolled from this controller.
6. Shift the Tuxedo Touch back to the primary
controller after enrolling Z-wave devices.
First, initiate the role shift on the handheld
controller from primary to secondary
referring to manufacturer's instructions.
Then, press the Z-Wave Secondary
Controller Shift to Primary icon on the
keypad.
7. Select the Z-Wave Basic Command Set On
icon to turn On all lamp modules, dimmer
On/Off switches and receptacles.
8. Select the Z-Wave Basic Command Set Off
icon to turn Off all lamp modules, dimmer
On/Off switches and receptacles.

NIGHT Setup Function

The NIGHT function can be set to arm the system in one of five arming modes:
• Away - Arms all zones with entry delay.
• Stay - Arms perimeter zones with entry delay.
• Instant - Arms perimeter zones without entry delay.
• Night (Residential Panels Only) – Arms all perimeter zones plus all zones listed in Zone List 5.
• Maximum - Arms all zones without entry delay. Not to be used for ANSI/SIA CP-01 installations.
To set the NIGHT function, do the following:
ICON
1. Press the System Setup and Advanced
Setup icon.
2. Enter your Authorized Code, if required.
3. Press the Night Setup icon.
4. Select the arming mode to be activated
when NIGHT is selected on the "Arming"
screen.

Output Setup Function

The Output Setup screen displays Output selections. There are a maximum of 18 outputs that can be
enabled or disabled. To set the Output Setup function, do the following:
User System Setup (cont'd)
ACTION
ACTION
31
NOTES
Select from two main categories of tests:
• Z-Wave Role Shifting: Primary to Secondary
and Secondary to Primary.
• Z-Wave Basic Command: Set On or Off.
A pop-up window is displayed with the following:
"
Role Shift is in progress, please wait ...
This Z-Wave controller shift function is for
evaluation only now. This primary controller
is shifting to the secondary.
The Shift is completed when the pop-up window
disappears.
Note: The Z-Wave Primary Controller Shift to
Secondary icon is inactive when the Tuxedo
Touch keypad becomes the secondary
controller.
Note: This command does not control door locks
or any other security enabled devices.
Note: This test may cause lights and thermostat
settings to change."
Note: This test may cause lights and thermostat
settings to change."
NOTES
Apply accepts the setting.
Back cancels your selection.