For the Installer

2.4.2 Removing the floor plate underneath the integral fuel hopper

– remove the 4 screws at the front and the 4 screws at the back of the base – Fig. 19.
– pull out and remove the floor plate – Fig. 20.
Fig. 19 Remove the screws

2.4.3 Removing control panel

– Fold up cladding cover. Loosen the 2 screws on the side of the control panel cover (Fig. 21) and lift the cover up
and off.
– Disconnect cable(s) from InfoWINplus on firing PCB and remove strain relief (cable ties) – Fig.22.
– Remove cladding cover control panel; remove 2 bolts with nuts (Fig. 23) and take off cover.
Fig. 21 Loosening 2 bolts, removing
control panel cover
– Remove boiler sensor, safety thermostat sensor and exhaust gas sensor, unscrew cover on rear wall (Fig. 24).
Pull boiler and safety thermostat sensor out of immersion sleeve, pull exhaust gas sensor out of protective
tube in flue outlet (Fig. 25). Guide all 3 sensors out of the cable duct.
Fig. 24 Removing cover
Fig. 20 Pull out and remove the floor plate
Cable(s)
Fig. 22 Disconnecting cable(s) from
InfoWINplus
Fig. 25 Pulling out sensor
13
Fig. 23 Unscrewing cladding cover