Sartorius IS 150 IGG-H Installation And Operating Instructions Manual

Weighing platforms

Advertisement

98648-006-06
Sartorius
IS 150 IGG-H, IS 150 IGG-H0CE
IS 300 IGG-H, IS 300IGG-H0CE
Weighing Platforms
Installation and Operating Instructions
98648-006-06

Advertisement

Table of Contents
loading

Summary of Contents for Sartorius IS 150 IGG-H

  • Page 1 98648-006-06 Sartorius IS 150 IGG-H, IS 150 IGG-H0CE IS 300 IGG-H, IS 300IGG-H0CE Weighing Platforms Installation and Operating Instructions 98648-006-06...
  • Page 2: Table Of Contents

    Legal Measuring Instrument Unpacking the Weighing Platform Declarations of Conformity Removing the Transport Locking Devices EC Verification – A Service Offered Leveling the Weighing Platform by Sartorius Connecting the Weighing Platform Accessories (Options) Safety Precautions Warm-up Time Operating Limits...
  • Page 3: General View Of The Weighing Platform

    General View of the Weighing Platform No. Designation Load plate Manufacturer's label Line voltage connector (optional) Leveling feet Level indicator Tag plate for metrological ID label Connecting cable (interface port/power supply)
  • Page 4: Warranty

    With this Sartorius IS weighing platform, you have acquired a high-quality weighing instrument that features advanced technology. As a rule, you will be using this weighing platform as part of a modular weighing system. Please read through these installation and operating instructions before operating your new weighing platform.
  • Page 5: Safety Instructions

    If you will be operating the platform outside the European Community in a Zone 2 hazardous area, you must comply with the national electrical code and applicable safety regulations of your country. Please ask your local Sartorius service technician, office or dealer for information on the currently valid regulations applicable in your country.
  • Page 6: Installation Instructions

    Installation Instructions Sartorius dealers or service technicians, who have received special training, will help you set up the weighing platform and show you how to operate it. Ambient Conditions Choose a suitable place to set up the weighing platform. Avoid exposing the weighing platform to the following ambient conditions: –...
  • Page 7: Getting Started

    Getting Started Unpacking the Weighing Platform Important Note To install the weighing platform in a pit, please observe the special requirements given in the section "Pit Installation." Unpacking the Weighing Platform − Remove the weighing platform and the load plate from the packaging −...
  • Page 8: Leveling The Weighing Platform

    Leveling the Weighing Platform Using the Level Indicator At the place of installation, level the weighing platform using the leveling feet so that the air bubble is centered within the circle of the level indicator. Check to ensure that all 4 leveling feet securely touch the surface and that they equally support the weight of the platform.
  • Page 9: Connecting The Weighing Platform

    Cable Lengths: Since you can choose to power the weighing platform via the interface port of the Sartorius isi industrial terminal or a separate power supply unit, there are a few restrictions that apply to the cable lengths between these components.
  • Page 10 The following diagrams show the options for powering weighing platforms and industrial terminals. Cables for connecting the industrial-grade AC adapter, model ING2, to the "IS" weighing platform without an extension cord (using the YDO50IS (3m) or YDO53IS (6m) data output port): Cables for connecting the industrial-grade AC adapter, model ING2, to the isi industrial terminal without an extension cord (using the YD050IS (3 m) or the YD053IS (6 m) data output port):...
  • Page 11: Safety Precautions

    Sartorius dealer or office. To use a main feeder cable from the ceiling or to mount a CEE plug, you will have to make arrangements inside your facilities for installation of such cable equipment.
  • Page 12: Warm-Up Time

    Whenever possible, avoid wiring your weighing platform into networks that carry a heavy electrical load (for instance, a compressor or similar equipment). Warm-up Time The weighing platform will need to warm up for at least 30 minutes after initial connection to the power supply (or after a relatively long period without power connection).
  • Page 13: Operating Limits

    Even though Sartorius weighing platforms feature a highly rugged construction, there are some limits. Avoid dropping objects from considerable height on the weighing platform and do not expose it to strong side impact. Sartorius weighing platforms withstand shock according to the shock response spectrum...
  • Page 14: General Instructions For Integration Into Conveyor Systems

    General Instructions for Integration into Conveyor Systems The IS weighing platform is suitable for installation in conveyor systems. Follow the general instructions given below and refer to the "Dimensions (Scale Drawings)" to meet the requirements for such installation. Secure the weighing platform using the appropriate components from the set of fasteners, YAS04 IS.
  • Page 15 Dimensions in millimeters...
  • Page 16: Pit Installation Of The Weighing Platform

    Pit Installation of the Weighing Platform Preparation Choose the appropriate pit frame from the list of accessories. Note to Users in the EU* If necessary, the weighing platform can be installed into the pit prior to initial verification. If a verified weighing platform has been installed, it must be subsequently verified in compliance with the applicable regulations of your country.
  • Page 17: Pit Construction Diagrams

    − Adjust the height by placing thin metal plates (7) underneath the pit frame. Back fill with concrete and allow area to dry. Positioning and Connecting the Weighing Platforms (Your Sartorius Service Technician Will Help You ) − Remove the load plate, the level indicator and leveling feet −...
  • Page 18: Installation Of The Drive-On Ramp Yar 10 Is

    Installation of the Drive-on Ramp YAR 10 IS To install the drive-on ramp, YAR 10 IS, use the angular braces and screws provided. Proceed as shown in the diagrams below. Loosely attach the angular braces (2) onto the frame of the weighing platform using the hexagon bolts M8x80 (1), nuts and washers.
  • Page 19: Configuring The Weighing Platform

    – and to perform optimally under various ambient conditions as well as process weighing data. For this reason, final configuration of your Sartorius Modular Technology equipment is possible only at your dealer's or your particular facilities.
  • Page 20: Specifications Chart

    Specifications Charts Access the configuration menu of the conected Sartorius terminal to set the code for the group of specifications of your choice. Please note that when you change the configuration, this may also change the preload range besides the weigh- ing capacity and the readability.
  • Page 21 IS 300 IGG-H0CE Weighing range structure SuperRange SingleRange Multi-Interval Weighing range Standard Configurable Maximum capacity, Max Readability 0 ... 30 kg 30 ... 60 kg 60 ...150 kg ± 6 ± 1.22 ± 0.62 ± 3 Zero tracking ± 2% ±10 ±10 ±10...
  • Page 22: General Specifications

    Net weight (without "isi" terminal) approx. Power requirements (optional) via A/C adapter, model ING2, 230 VAC or 115 VAC (to be connected by your dealer or a Sartorius service technician only) Frequency 48 – 63 Power consumption 34: maximum, 18: average...
  • Page 23 Selecting and Attaching ID Plates The ID plate is to be selected and attached according to the specification block (configuration of scales) and the display and control unit (terminal). For details of how to position the ID plate on the scales or tag holder, refer to the instructions in "Plates and Markings".
  • Page 24: Pin Assignment Chart For The Rs-985 Interface

    Pin Assignment Chart for the Interface RS-485 RS-485, 3-m Cable Male Connector: Type C091D, 12-pin round connector with threaded locking ring, Amphenol (IP67)) Pin Assignment RxD-TxD-N Not Connected Not Connected Not Connected Signal GND Menu Access Switch for Calibration/ Adjustment (routed externally) VCC (24V Power Supply) Not Connected GND (24V Power Supply)
  • Page 25: Troubleshooting Guide

    Troubleshooting Guide (For Problems That You Can Fix Yourself) Problem Possible Causes Solution No segments appear on the – No line current is available – Check the power supply display – The AC adapter is not plugged – Plug the AC adapter into the platform and into an electrical outlet –...
  • Page 26 – The weighing platform was not – Tare before weighing tared before weighing – The weighing platform is tilted – Level the weighing platform as described in the instructions If any other errors occur, please contact your nearest Sartorius service center or your dealer.
  • Page 27: Care And Maintenance

    Care and Maintenance Servicing Regular servicing by a Sartorius technician will extend the service life of your weighing platform and ensure its continued weighing accuracy. Sartorius can offer you service contracts, with your choice of regular maintenance intervals ranging from 1 month to 2 years.
  • Page 28: Safety Inspection

    – the power supply has been stored for a relatively long period under conditions that are different from those specified for "Storage and Shipping" In this case, notify your nearest Sartorius Service Center or the International Technical Support Unit based in Goettingen, Germany. Only service...
  • Page 36: Use Of The Weighing Platform As A Legal Measuring Instrument

    Therefore, a legal weighing instrument can consist of the following: – a Sartorius isi industrial terminal + 1 to 3 IS weighing platforms – a Sartorius isi industrial terminal + at least 1 weighing platform + up to 2 further EC- or nationally type-approved weighing instruments As a weighing instrument, the weighing platform is not allowed to be used for weighing goods intended for direct sale to the public.
  • Page 37 To have your weighing platform verified, you must change the preload setting before verification only. The legal basis permitting Sartorius to perform initial verification is constituted by the following: 1) EC Council Directive No. 2009/23/EC on non- automatic weighing instruments, which has been applicable within the harmonized Internal Market of the European Union since 1 January 1993;...
  • Page 38 PC device for data transfer to a central computer, or a similar device. Information Concerning the EC Machinery Directive Sartorius balances, scales and weighing platforms are not machines in the sense of the EC Machinery Directive; however, as individual instruments they meet the safety requirements of this Directive.
  • Page 41: Declarations Of Conformity

    Important Note: The operator shall be responsible for any modifications to Sartorius equipment and for any connections of equipment not supplied by Sartorius and must check and, if necessary, correct these modifications and connections. On request, Sartorius will provide information on the minimum operating specifications (in accordance with the Standards listed above for defined immunity to interference).
  • Page 42 – price calculation For the respective Declaration of Type Conformity for weighing instruments that have been verified by Sartorius for use as legal measuring instruments and that have an EC Type-Approval Certificate, see page 37. This Directive also regulates the performance of the EC verification by the...
  • Page 47: "Ec Verification" - A Service Offered By Sartorius

    – Inspection – Training – Initial verification If you would like Sartorius to perform initial verification of your weighing instrument, contact an authorized service representative. Please refer to the Sartorius European Service Center Addresses on page 39. Subsequent Verifications within the European Countries The validity of the verification will become void in accordance with the national regulations of the country in which the weighing instrument is used.
  • Page 48: Accessories (Options)

    C091D, 12-contact, Amphenol Round male connector, IP65, 69 QC0010 type C091D, 12-pin, Amphenol Adapter cable, from round connector to PC, YCC 01-0017D2 25-pin D-Submini, 0.2 m long (YDO52IS required) For ordering customized cables and accessories, contact your local Sartorius office or dealer.
  • Page 49 PC adapter cable, 25-pin D-Submini – 9-contact 6965619 D-Submini 0.25 m long (YDO 52 IS and YCC 01-0017D2 required) Special menu access locking device, IP65 (for YAS 02 IS legal metrology); for external positioning of the menu access lock on weighing platforms built into systems. If this device is used, a tag plate for ID labels is not required.
  • Page 50 Drive-on ramp (1,250 x 600 mm) YAR 10 IS Pit frames – Stainless steel YEG 01 IP – Painted YEG 04 IP Set of fasteners for pit frame installation YAS 04 IS For ordering customized cables and accessories, contact your local Sartorius office or dealer.
  • Page 52 Sartorius Weighing Technology GmbH Weender Landstraße 94-108 37075 Goettingen, Germany Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius-mechatronics.com Copyright by Sartorius, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius.

This manual is also suitable for:

Is 300igg-h0ceIs 150 igg-h0ceIs 300 igg-h

Table of Contents