Sartorius IS16EDE-H Installation And Operating Instructions Manual

Sartorius IS16EDE-H Installation And Operating Instructions Manual

Weighing platform for display and control unit for standard use or verified for use in legal metrology

Advertisement

98648-010-27
Sartorius
IS16EDE-H, IS16EDE-H0CE, IS34EDE-H, IS34EDE-H0CE,
IS64EDE-H, IS64EDE-S, IS64EDE-H0CE
Weighing Platform for Display and Control Unit
for Standard Use or Verified for Use in Legal Metrology
Installation and Operating Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IS16EDE-H and is the answer not in the manual?

Questions and answers

Summary of Contents for Sartorius IS16EDE-H

  • Page 1 98648-010-27 Sartorius IS16EDE-H, IS16EDE-H0CE, IS34EDE-H, IS34EDE-H0CE, IS64EDE-H, IS64EDE-S, IS64EDE-H0CE Weighing Platform for Display and Control Unit for Standard Use or Verified for Use in Legal Metrology Installation and Operating Instructions...
  • Page 2: Table Of Contents

    Weighing System Components Warranty Effect of the Preload on Verifiability Storage and Shipping Conditions ”EC Verification” - A Service Offered by Safety Instructions Sartorius Installation Instructions Subsequent Verifications within the Ambient Conditions European Countries Conditioning the Weighing Platform IP65 Protection...
  • Page 3: General View Of The Weighing Platform

    General View General View of the Weighing Platform No. Designation No. Designation Load plate Connecting cable Manufacturer’s label (interface port/power supply) Metrological ID labels (only on weighing Valve for barometric pressure compensation platforms verifiable or verified for use in Blank for power supply cable gland legal metrology) (optional) Leveling feet...
  • Page 4: Intended Use

    Safety Instructions The equipment may be opened only by authorized service technicians who have been trained by Sartorius and who perform repair or maintenance work in accordance with Sartorius’ standard operating procedures. –...
  • Page 5: Installation Instructions

    Installation Instructions Installation Instructions The equipment must be installed and put into operation by a trained Sartorius dealer or service technician, who will also show you how to work with it. Ambient Conditions Choose a suitable place to set up the weighing platform. Avoid exposing the weighing platform to the following ambient conditions: –...
  • Page 6: Getting Started

    Because you can choose whether to power the weighing platform via the interface port of the display and control unit or using a separate AC adapter (adapter kit required; must be installed by a Sartorius service technician), some restrictions apply to the cable lengths permissible between components.
  • Page 7: Separate Power Connection For The Weighing Platform (Optional)

    Getting Started Separate Power Connection (Optional) for the Weighing Platform An adapter kit must be installed by a Sartorius dealer or service technician to connect the weighing platform separately to line current (mains supply). In addition, this separate power connection is required if you interface the weighing platform directly with a computer.
  • Page 8: Safety Precautions

    Sartorius office or dealer. To use a main feeder cable from the ceiling or to mount a CEE plug, you will have to make arrangements inside your facilities for installation of such cable equipment.
  • Page 9: Warmup Time

    Avoid dropping objects from a considerable height onto the weighing platform and do not expose the platform to strong side impact. Sartorius weighing platforms are shock resistant in accordance with the shock response spectrum defined in the IEC68 standard, Part 2-27.
  • Page 10: General Instructions For Integration Into Conveyor Systems

    You can use either of the following as a display and control unit with your IS weighing platform: – Sartorius isi industrial terminal – Computer with a special Sartorius configuration program (see “Accessories”) The configuration options for your weighing platform are listed in the “Specifications Chart” on the following pages.
  • Page 11: Specifications Charts

    Specifications Charts Access the configuration menu of the Sartorius industrial terminal or display and control unit of your choice. You need to set the appropriate codes before verification of the platform as a legal measuring instrument. Please note that when you change the configuration, this may also change the accuracy class besides the weighing capacity and the readability.
  • Page 12 IS34EDE-H0CE (module, type BFBF/ together with the isi operator and indicating terminal (industrial terminal) or a PC with Sartorius software of the type isoTEST), verifiable for use in legal metrology Specifications group Spec. gp.1 Spec. gp.2* Spec. gp.3 Spec. gp.4 Spec.
  • Page 13 * = factory setting IS 64 EDE-H0CEH0CE (module, type BF BF together with the isi operator and indicating terminal (industrial terminal) or a PC with Sartorius software of the type isoTEST), verifiable for use in legal metrology Specifications group Spec. gp.5 Spec.
  • Page 14: General Specifications

    General Specifications (applicable for use in standard applications, not in legal metrology) Model IS 16 EDE-H IS 34 EDE-H IS 64 EDE-S IS64EDE-H Maximum capacity Readability ≤ ≤ ≤ ≤ Linearity ±0.2 ±0.2 ±0.5 ±0.3 ≤ ≤ ≤ ≤ Repeatability ±0.05 ±0.1 ±0.3...
  • Page 15: Selecting And Affixing The Respective Id Label

    Specifications Chards Selecting and Affixing the Respective ID Label Select the respective metrology ID label according to the accuracy class of your choice and affix it to the platform to be verified. Pin Assignment Chart for the RS-485 Interface Cable length: 3 m (approx. 10 ft.) Male connector: Type C091D, 12-pin round connector with threaded locking ring, Amphenol (IP65)
  • Page 16: Troubleshooting Guide

    Troubleshooting Guide Problem Possible Causes Solution No segments appear on the No line current is available Check the power supply display The AC adapter is not plugged Plug the AC adapter into the platform and into an electrical outlet The weighing platform has Turn on the display and been in standby mode for control unit...
  • Page 17 Adjust/calibrate the result is obviously wrong adjusted/calibrated before weighing platform weighing The weighing platform is not level Level the weighing platform as described in the instructions If any other errors occur, please contact your local Sartorius dealer or Sartorius Service Center.
  • Page 18: Care And Maintenance

    Care and Maintenance Service Regular servicing by a Sartorius technician will extend the service life of your weighing platform and ensure its continued weighing accuracy. Sartorius can offer you service contracts, with your choice of regular maintenance intervals ranging from 6 months to 2 years.
  • Page 19: Instructions For Recycling The Packaging

    Care and Maintenance In this case, notify your nearest Sartorius Service Center or the International Technical Support Unit based in Goettingen, Germany. Maintenance and repair work may be performed only by authorized Sartorius service technicians who have access to the required maintenance manuals and have attended the relevant service training courses.
  • Page 21: Declaration Of Conformity

    Calibration/Adjustment”). The preload can be changed only prior to verification. The legal basis permitting Sartorius to perform initial verification is constituted by the following: 1) EC council directive no. 90/384/EEC on non-automatic weighing instruments, which has been applicable within the harmonized Single Market of the European Union since 1 January 1993;...
  • Page 22: Ec Verification" - A Service Offered By Sartorius

    For information on verification and legal regulations currently applicable in your country, and to obtain the names of the persons to contact, please contact your local Sartorius office, dealer or service center.
  • Page 23: Ec Type Approval Certificate

    Certificates EC Type Approval Certificate including the Signatories of the Agreement on the European Economic Area...
  • Page 25 Certificates...
  • Page 26: Plates And Markings

    Plates and Markings...
  • Page 27: Dimensions (Scale Drawings)

    Plates and Markings Dimensions (Scale Drawings) All dimensions given in millimeters Ø...
  • Page 28: Accessories (Options)

    PC adapter cable, 25-pin D-Submini to 9-contact 69 65619 D-Submini; length: 0.2 m (approx. 8 in.) (YDO 52 IS interface port and YCC 01-0017D2 adapter cable required) To order customized accessories or custom solutions, please contact the Sartorius “Fast Factory”.
  • Page 29 Configuration diskette for the IS weighing YAD 01 IS platform (PC, DOS), without interface cable Hanger for under-scale weighing 69EA0040 To order customized accessories or custom solutions, please contact the Sartorius “Fast Factory”.
  • Page 32 All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG. The status of the information, specifications and illustrations in this manual is indicated by the date given below.