Cs Zone Reporting Options - NAPCO Gemini GEM-P816 Programming Instructions Manual

Table of Contents

Advertisement

CS ZON E REP OR TING OP TI ONS (A DDRESS 07 2 0-0 735 )
ADDRESS 0720-0727
CONTROL PANEL ZONES REPORT CODE
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
0720
0721
0722
0723
Default for Group Zone Report Codes depends on Easy Menu Question "RCVR. FORMAT".
ZONE REPORT
CODE OPTIONS
DATA ENTRIES
DATA
ENTRIES
MODEM CODE
LEFT
1
Fire
2
Panic
3
Burglary
4
Hold up
7
Gas Alarm
8
Heat Alarm
0
Auxiliary Alarm
B
24 Hour Auxiliary
NAPCO Security Systems
R
0724
0725
0726
0727
PULSE EVENT CODE will be the first digit of the 2 digit reporting code. The second digit will be the
second digit of the reporting zone. For example, for zone 9 (address 0728), if the right digit is "3", then
the reporting code is "39". For example, for zone 15 (address 0734), if the right digit is "4", then the
reporting code is "45".
MODEM CODES determine the zone types reported for the following formats: SIA and ADEMCO Point ID.
1. Select the desired Modem Code for each zone from the table shown.
U
2. Press
to save.
ADDRESS 0728-0731
ZONES REPORT CODE
ZONE 9 ZONE 10 ZONE 11 ZONE 12
0728
0729
0730
0731
GEM-P816 Programming Instructions
Page 23
ADDRESS 0732-0735
ZONES REPORT CODE
ZONE 13 ZONE 14 ZONE 15 ZONE 16
0732
0733
0734
0735