Keyfob Transmitters as Zone Input Devices

(Refer to display above: press the AWAY button to go backwards).
Each of the 4 keyfob buttons can be assigned to a zone. For example, On button = point 1; Off button =
point 2; A1 = point 3; A2 = point 4. Up to 16 keyfobs (using 1 button) or 8 keyfobs (using 2 buttons) or 4
keyfobs (using all 4 buttons) or any combination up to a maximum of 16 controlled zones can be assigned,
providing multiple wireless panic buttons on a system, each reporting to a Central Station or a pager and/or
annunciating on a keypad the keyfob zone number with a description. To assign a keyfob to a zone: pro-
gram the keyfob as you would a transmitter, entering the keyfob's ID code, check sum and point number at
the appropriate zone. The "Quick Method" is not allowed. The zone may be hardwired to an electrical
sensor as well as assigned to a keyfob (either one will activate the zone alarm output). NOTE: If assigning
a keyfob to a zone, the "ON/OFF" buttons on the keyfob will no longer arm/disarm the system. The keyfob
is converted to a "panic only" device.
0 1 -
(Direct Entry)
Zone Descriptions can only be entered through the GEM-RP1CAe2 Keypad or by using the Napco Quickloader Software. See
Easy Menu Programming Worksheet for available zone description characters.

Enter Date

(
/
/
)
(Direct Entry)

Enter Time

(
:
)
(Direct Entry)
D e a l e r C o d e
4 5 6 7 8 9
D E A L E R C O D E
R E - E N T E R
T E S T T I M E R
S M T W T F S H H : M M
EXIT DEALER PROGRAM MODE: This completes the custom default program. Press
Mode for further programming or press
CLEAR PROGRAM: Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press
to enter the Address Program Mode; (b) access Location 2285 (Clear Program) or 2286 (Cold Start); (c) press
C
(d) press
to exit the Dealer Program Mode. A "SYSTEM TROUBLE/E09-00 SERVICE" will occur. Press
C
2 2 8 5 X X
2 2 8 6 X X
GEM-P816 Programming Instructions

Enter Zone Descriptions

For each zone, enter a description of up to two lines. Press
See page 41 for instructions for entering characters and numbers for the zone descriptions.
To proceed to the next description, place the cursor under the Zone Number (e.g. "1") and
press the number that corresponds to the zone. Program new description as above. NOTE:
Enter Date (Press
R
Enter the current date in the format MM/DD/YY. (MM = month, DD = day and YY = year.
U
Press
to save. Press the NEXT/YES button to proceed.
Enter Time (Press
R
Enter the current time in format HH:MMA/P, where HH=hours (01–12); MM=minutes (00–59).
Select AM or PM by pressing any number button.
U
Press
to save. Press the NEXT/YES button to proceed.

Dealer Code

Directly enter the Dealer Code (default = 456789), using
U
Press
to save. Re-enter the Dealer Code to verify the previous code. Press
Press the NEXT/YES button to proceed.

Test Timer

Select day(s) by simply erasing the unwanted days. Move the cursor over the day and
press any number key to erase/restore the day. For example, "Monday" and "Friday" will
appear as: "•
• • •
M
Enter Time (in 24 hour format) by moving cursor under the left H and pressing two digits to over-
write the existing default of 00. Note: Midnight is 00:00. Enter minutes by continuing to enter
data or if just updating minutes move the cursor under the left M and enter the two digits to over-
write the existing default of 00. Use
once again to end all programming and resume normal keypad operation.
C
Clear Dealer Program (Erases Dealer Program)
Use this feature to erase the Panel Program, while maintaining Scheduled Data and Zone Descrip-
tions. Access address 2285 and press
H
Menu Driven Program Mode to reprogram system.
Cold Start (Erases Entire Program)
This erases all programmed data (Dealer Program, Zone Description Data and Schedules).
Access address 2286 and press
H
(schedules) can only be programmed again with the Downloading Software.
to set cursor).
to set cursor.)
•"
F
as right cursor one position.
R
U
. Data entry is not allowed. NOTE: Enter Easy
U
. Data entry is not allowed. NOTE: Some features
DATA
AUX 1/AUX 2
ENTRY
0
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
9
Keypad Panic
A
Keypad Aux.
B
C
PGM2 Ouput Toggle
D
Access on PGM2 Output
E
Arm STAY
F
Interior Button
U
to save each description.
through
0
9
to enter the Direct Address Program
C