(2) Detaching and refitting the power source PWB

Procedure
1. Remove the left cover (See page 1-5-
3).
2. Remove the wires from three clamps.
3. Remove five connectors from the power
source PWB.
4. Unhook four hooks and then remove
the frame left duct.
5. Remove the wire from the clamp.
Clamp
Connectors
YC105
YC108
Frame left duct
Hook
Clamp
Wires
Hook
1-5-40
2PK/2PL/2PM/2PN
Clamps
Power source
PWB
Power source
YC107
PWB
YC104
YC106
Figure 1-5-59
Hook
Hook
Frame left duct
Figure 1-5-60