Adjusting the scanner leading edge registration (alternative command for the maintenance U066)
Description
Adjusts the scanner leading edge registration of the original scanning.
Purpose
Make the adjustment if there is a regular error between the leading edges of the copy image and original.
Format
!R! KCFG "SCAN",5,#1,#2;;EXIT;
Parameter
#1
1: Scanner leading edge registration
2: Scanner leading edge registration of rotated scan
#2
Adjustable range: -45 to 45 (in 0.086mm increment) (0: default)
Example: Scanner leading edge registration set to 10 to increase 0.86mm
!R! KCFG "SCAN",5,1,"10";EXIT;
Scanner leading edge registration (within ± 2.5 mm)
Original
Copy
Copy
example 1
example 2
2-4-15
2PK/2PL/2PM/2PN