(3) Detaching and refitting the power source PWB
Procedure
1. Remove the right cover and left cover.
(See page 1-5-3)
2. Remove the drum unit.
(See page 1-5-26)
3. Remove three connectors from the
relay PWB.
4. Release three clamps and then remove
the wires.
Reley PWB
Connectors
Clamps
1-5-37
YC2
YC1
YC3
Clamp
Wires
Figure 1-5-57
2MF/2MG