2H9
(2) Detaching and refitting the power source PWB
Procedure
1. Remove the left cover (See page 1-5-3).
2. Remove the wires from three clamps.
3. Remove five connectors from the power
source PWB.
4. Unhook four hooks and then remove the
frame left duct.
5. Remove the wire from the clamp.
1-5-42
Clamp
Connectors
YC105
YC108
Frame left duct
Hook
Clamp
Wires
Hook
Clamps
Power source
PWB
YC107
YC106
YC104
Figure 1-5-63
Hook
Hook
Frame left duct
Figure 1-5-64
Power source
PWB
Connectors