(2) Detaching and refitting the power source PWB

Procedure
1. Remove the left cover (See page 1-5-4).
2. Remove four connectors.
3. Remove four P tight screws, two screws and
ground terminal.
4. Remove the power source PWB assembly
from the high voltage PWB's connector.
1-5-22
Connector
Ground
terminal
Screws
Connector
(YC103)
P tight screws
Power source
PWB assembly
P tight screws
Connector
Connector
Connector
Figure 1-5-30
High voltage PWB
Figure 1-5-31
Connector
(YC201)