4 About the units and options
Languages on the user interface can be uploaded by PC software or
copied from an user interface to the other.
For installation instructions, see
interface" on
page 45.
Simplified user interface (EKRUCBS)
▪ The simplified user interface can only be used in combination with
the main user interface.
▪ The simplified user interface acts as room thermostat and needs
to be installed in the room that you want it to control.
For installation instructions, see the installation and operation
manual of the simplified user interface.
Room thermostat (EKRTWA, EKRTR1)
You can connect an optional room thermostat to the indoor unit. This
thermostat can either be wired (EKRTWA) or wireless (EKRTR1).
For installation instructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use a wireless indoor temperature sensor (EKRTETS) only
in combination with the wireless thermostat (EKRTR1).
For installation intructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Digital I/O PCB (EKRP1HB)
The digital I/O PCB is required to provide following signals:
▪ Alarm output
▪ Space heating/cooling On/OFF output
▪ Changeover to external heat source
▪ Only for EHVH/X11+16 models: Control signal for bottom plate
heater kit EKBPHTH16A.
For installation instructions, see the installation manual of the digital
I/O PCB and addendum book for optional equipment.
Demand PCB (EKRP1AHTA)
To enable the power saving consumption control by digital inputs
you must install the demand PCB.
For installation instructions, see the installation manual of the
demand PCB and addendum book for optional equipment.
Remote indoor sensor (KRCS01-1)
By default the internal user interface sensor will be used as room
temperature sensor.
As an option the remote indoor sensor can be installed to measure
the room temperature on another location.
For installation instructions, see the installation manual of the remote
indoor sensor and addendum book for optional equipment.
4.3.3

Possible combinations of indoor unit and outdoor unit

Outdoor unit
ERHQ011+ERLQ011
ERHQ014+ERLQ014
4.3.4

Possible combinations of indoor unit and domestic hot water tank

Indoor unit
EHBH16CB3V
EHBX16CB3V
EHBH16CB9W
Installer reference guide
10
"7.9.11  To connect the user
Indoor unit
EHBH/X11
EHBH/X16
O
O
EKHWS
O
O
O
INFORMATION
▪ The remote indoor sensor can only be used in case the
user interface is configured with room thermostat
functionality.
▪ You can only connect either the remote indoor sensor
or the remote outdoor sensor.
Remote outdoor sensor (EKRSCA1)
By default the sensor inside the outdoor unit will be used to measure
the outdoor temperature.
As an option the remote outdoor sensor can be installed to measure
the outdoor temperature on another location (e.g. to avoid direct
sunlight) to have an improved system behaviour.
For installation instructions, see the installation manual of the remote
outdoor sensor.
INFORMATION
You can only connect either the remote indoor sensor or
the remote outdoor sensor.
PC configurator (EKPCCAB)
The PC cable makes a connection between the switch box of the
indoor unit and a PC. It gives the possibility to upload different
language files to the user interface and indoor parameters to the
indoor unit. For the available language files, contact your local
dealer.
The software and corresponding operating instructions are available
on
http://www.daikineurope.com/support-and-manuals/software-
downloads/.
For installation instructions, see the installation manual of the PC
cable and
"8 Configuration" on
Drain pan kit (EKHBDPCA2)
The drain pan is required to drain accumulated condensation from
the indoor unit. It is required during low temperature cooling
operation of the indoor unit and when the leaving water temperature
is <18°C.
For installation instructions, see the installation manual of the drain
pan kit.
Solar kit (EKSOLHW)
The solar kit is required to connect the solar application with the
domestic hot water tank.
For installation, see the installation manual of the solar kit and
addendum book for optional equipment.
Domestic hot water tank
The domestic hot water tank can be connected to the indoor unit for
providing domestic hot water.
Outdoor unit
ERHQ016+ERLQ016
Domestic hot water tank
EKHWSU
EKHWE
O
O
O
page 48.
Indoor unit
EHBH/X11
EHBH/X16
EKHWET
O
O
O
O
O
O
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01