Field settings table
Breadcrumb
Field code
Setting name
A.8
[A-02]
--
A.8
[A-03]
--
A.8
[A-04]
--
A.8
[B-00]
--
A.8
[B-01]
--
A.8
[B-02]
--
A.8
[B-03]
--
A.8
[B-04]
--
A.8
[C-00]
Domestic heating water priority.
A.8
[C-01]
--
A.8
[C-02]
Is an external backup heat source connected?
A.8
[C-03]
Bivalent activation temperature.
A.8
[C-04]
Bivalent hysteresis temperature.
A.8
[C-05]
What is the thermo request contact type for the main zone?
A.8
[C-06]
What is the thermo request contact type for the add. zone?
A.8
[C-07]
What is the unit control method in space operation?
A.8
[C-08]
Which type of external sensor is installed?
A.8
[C-09]
What is the required alarm output contact type?
A.8
[C-0A]
--
A.8
[C-0C]
High electricity price decimal (Do not use)
A.8
[C-0D]
Medium electricity price decimal (Do not use)
A.8
[C-0E]
Low electricity price decimal (Do not use)
A.8
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
A.8
[D-01]
Contact type of preferential kWh rate PS installation?
A.8
[D-02]
Which type of DHW pump is installed?
A.8
[D-03]
Leaving water temperature compensation around 0°C.
A.8
[D-04]
Is a demand PCB connected?
A.8
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
A.8
[D-07]
Is a solar kit connected?
A.8
[D-08]
Is an external kWh meter used for power measurement?
A.8
[D-09]
Is an external kWh meter used for power measurement?
A.8
[D-0A]
--
A.8
[D-0B]
--
A.8
[D-0C]
What is the high electricity price (Do not use)
A.8
[D-0D]
What is the medium electricity price (Do not use)
A.8
[D-0E]
What is the low electricity price (Do not use)
A.8
[E-00]
Which type of unit is installed?
A.8
[E-01]
Which type of compressor is installed?
A.8
[E-02]
What is the indoor unit software type?
A.8
[E-03]
What is the number of backup heater steps?
A.8
[E-04]
Is the power saving function available on the outdoor unit?
A.8
[E-05]
Can the system prepare domestic hot water?
A.8
[E-06]
Is a DHW tank installed in the system?
A.8
[E-07]
What kind of DHW tank is installed?
A.8
[E-08]
Power saving function for outdoor unit.
A.8
[E-09]
--
A.8
[E-0A]
--
4P383508-1 - 2015.01
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/O
R/O
R/O
R/O
R/O
R/W
R/O
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0 (*5)
1 (*6)
0
0
0
0
0
0
0
0: Solar priority
1: Heat pump priority
0
0: No
1: Bivalent
2: -
3: -
-25~25°C, step: 1°C
0°C
2~10°C, step: 1°C
3°C
1: Thermo ON/OFF
2: C/H request
0: -
1: Thermo ON/OFF
2: C/H request
0: LWT control
1: Ext RT control
2: RT control
0: No
1: Outdoor sensor
2: Room sensor
0: Normally open
1: Normally closed
0
0~7
0
0~7
0
0~7
0
0: None
1: BSH only
2: BUH only
3: All heaters
0: No
1: Active open
2: Active closed
0: No
1: Secondary rtrn
2: Disinf. shunt
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
0: No
1: Pwr consmp ctrl
0: Forced off
1: As normal
0: No
1: Yes
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0
2
0~49
0
0~49
0
0~49
0
0~5
0: LT split
0: 8
1: 16
0: Type 1
1: Type 2
0: No BUH
1: 1 step
2: 2 steps
0: No
1: Yes
0: No (*1)
1: Yes (*2)
0: No
1: Yes
0~6
0: Type 1 (*1)
1: Type 2 (*2)
0: Disabled (*6)
1: Enabled (*5)
0
0
Installer setting at variance with
default value
Date
Value
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*