Field settings table
Breadcrumb
Field code
Setting name
A.2.1.5
[5-0D]
BUH type
A.2.1.6
[D-01]
Preferential kWh rate
A.2.1.7
[C-07]
Unit control method
A.2.1.8
[7-02]
Number of LWT zones
A.2.1.9
[F-0D]
Pump operation mode
A.2.1.A
[E-04]
Power saving possible
A.2.1.B
User interface location
└─ Options
A.2.2.1
[E-05]
DHW operation
A.2.2.3
[E-07]
DHW tank type
A.2.2.4
[C-05]
Contact type main
A.2.2.5
[C-06]
Contact type add.
A.2.2.6.1
[C-02]
Digital I/O PCB
A.2.2.6.2
[D-07]
Digital I/O PCB
A.2.2.6.3
[C-09]
Digital I/O PCB
A.2.2.6.4
[F-04]
Digital I/O PCB
A.2.2.7
[D-04]
Demand PCB
A.2.2.8
[D-08]
External kWh meter 1
A.2.2.9
[D-09]
External kWh meter 2
A.2.2.A
[D-02]
DHW pump
A.2.2.B
[C-08]
External sensor
A.2.2.D
[E-0B]
Bi-zone kit
└─ Capacities
A.2.3.1
[6-02]
Booster heater
A.2.3.2
[6-03]
BUH: step 1
A.2.3.3
[6-04]
BUH: step 2
A.2.3.6
[6-07]
Bottom plate heater
Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1
LWT setpoint mode
A.3.1.1.2.1
[9-01]
Temperature range
A.3.1.1.2.2
[9-00]
Temperature range
A.3.1.1.2.3
[9-03]
Temperature range
A.3.1.1.2.4
[9-02]
Temperature range
A.3.1.1.5
[8-05]
Modulated LWT
A.3.1.1.6.1
[F-0B]
Shut-off valve
A.3.1.1.6.2
[F-0C]
Shut-off valve
A.3.1.1.7
[9-0B]
Emitter type
└────────────────── Additional
A.3.1.2.1
LWT setpoint mode
A.3.1.2.2.1
[9-05]
Temperature range
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
Ext. backup heat src
Solar kit
Alarm output
Bottom plate heater
Is a bi-zone kit installed?
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (cooling)
Maximum temp (cooling)
Thermo On/OFF
Cooling
Minimum temp (heating)
(#) Setting is not applicable for this unit.
Range, step
Default value
R/W
0: 1P,(1/2)
1: 1P,(1/1+2)
2: 3P,(1/2)
3: 3P,(1/1+2) (*3)
4: 3PN,(1/2)
5: 3PN,(1/1+2) (*4)
R/W
0: No
1: Active open
2: Active closed
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: 1 LWT zone
1: 2 LWT zones
R/W
0: Continuous
1: Sample
2: Request
R/O
0: No
1: Yes
R/W
0: At unit
1: In room
R/W
0: No (*1)
1: Yes (*2)
R/W
0~6
0: Type 1 (*1)
1: Type 2 (*2)
R/W
1: Thermo ON/OFF
2: C/H request
R/W
1: Thermo ON/OFF
2: C/H request
R/W
0: No
1: Bivalent
2: -
3: -
R/W
0: No
1: Yes
R/W
0: Normally open
1: Normally closed
R/W
0: No
1: Yes
R/W
0: No
1: Pwr consmp ctrl
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/O
0: No (#)
R/W
0~10kW, step: 0,2kW
0kW
R/W
0~10kW, step: 0,2kW
3kW
R/W
0~10kW, step: 0,2kW
0kW (*3)
6kW (*4)
R/W
0~200W, step: 10W
0W
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~depending on outdoor unit, step: 1°C
55°C
R/W
5~18°C, step: 1°C
5°C
R/W
18~22°C, step: 1°C
22°C
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: Quick
1: Slow
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
3/9
Installer setting at variance with
default value
Date
Value