Field settings table
Breadcrumb
Field code
Setting name
A.8
[6-02]
What is the capacity of the booster heater?
A.8
[6-03]
What is the capacity of the backup heater step 1?
A.8
[6-04]
What is the capacity of the backup heater step 2?
A.8
[6-05]
--
A.8
[6-06]
--
A.8
[6-07]
What is the capacity of the bottom plate heater?
A.8
[6-08]
What is the hysteresis to be used in reheat mode?
A.8
[6-09]
--
A.8
[6-0A]
What is the desired comfort storage temperature?
A.8
[6-0B]
What is the desired eco storage temperature?
A.8
[6-0C]
What is the desired reheat temperature?
A.8
[6-0D]
What is the desired DHW production type?
A.8
[6-0E]
What is the maximum temperature setpoint?
A.8
[7-00]
Domestic hot water booster heater overshoot temperature.
A.8
[7-01]
Domestic hot water booster heater hysteresis.
A.8
[7-02]
How many leaving water temperature zones are there?
A.8
[7-03]
--
A.8
[7-04]
--
A.8
[7-05]
Boiler efficiency
A.8
[8-00]
--
A.8
[8-01]
Maximum running time for domestic hot water operation.
A.8
[8-02]
Anti-recycling time.
A.8
[8-03]
Booster heater delay timer.
A.8
[8-04]
Additional running time for the maximum running time.
A.8
[8-05]
Allow modulation of the LWT to control the room temp?
A.8
[8-06]
Leaving water temperature maximum modulation.
A.8
[8-07]
What is the desired comfort main LWT in cooling?
A.8
[8-08]
What is the desired eco main LWT in cooling?
A.8
[8-09]
What is the desired comfort main LWT in heating?
A.8
[8-0A]
What is the desired eco main LWT in heating?
A.8
[8-0B]
--
A.8
[8-0C]
--
A.8
[8-0D]
--
A.8
[9-00]
What is the maximum desired LWT for main zone in heating?
A.8
[9-01]
What is the mimimum desired LWT for main zone in heating?
A.8
[9-02]
What is the maximum desired LWT for main zone in cooling?
A.8
[9-03]
What is the mimimum desired LWT for main zone in cooling?
A.8
[9-04]
Leaving water temperature overshoot temperature.
A.8
[9-05]
What is the mimimum desired LWT for add. zone in heating?
A.8
[9-06]
What is the maximum desired LWT for add. zone in heating?
A.8
[9-07]
What is the mimimum desired LWT for add. zone in cooling?
A.8
[9-08]
What is the maximum desired LWT for add. zone in cooling?
A.8
[9-09]
What is the desired delta T in heating?
A.8
[9-0A]
What is the desired delta T in cooling?
A.8
[9-0B]
What emitter type is connected to the main LWT zone?
A.8
[9-0C]
Room temperature hysteresis.
A.8
[9-0D]
Pump speed limitation
A.8
[9-0E]
--
A.8
[A-00]
--
A.8
[A-01]
--
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0~10kW, step: 0,2kW
0kW
0~10kW, step: 0,2kW
3kW
0~10kW, step: 0,2kW
0kW (*3)
6kW (*4)
0
0
0~200W, step: 10W
0W
2~20°C, step: 1°C
10°C
0
30~[6-0E]°C, step: 1°C
60°C
30~min(50, [6-0E])°C, step: 1°C
45°C
30~min(50, [6-0E])°C, step: 1°C
45°C
0: Reheat only
1: Reheat + sched.
2: Scheduled only
[E-07]≠1 : 40~80°C, step: 1°C
60°C
[E-07]=1 : 40~60°C, step: 1°C
60°C
0~4°C, step: 1°C
0°C
2~40°C, step: 1°C
2°C
0: 1 LWT zone
1: 2 LWT zones
2,5
0
0: Very high
1: High
2: Medium
3: Low
4: Very low
1 min
5~95 min, step: 5 min
30 min
0~10 hour, step: 0,5 hour
0,5 hour [E-07]=1
3 hour [E-07]≠1
20~95 min, step: 5 min
50 min
0~95 min, step: 5 min
95 min
0: No
1: Yes
0~10°C, step: 1°C
3°C
[9-03]~[9-02], step: 1°C
18°C
[9-03]~[9-02], step: 1°C
20°C
[9-01]~[9-00], step: 1°C
35°C
[9-01]~[9-00], step: 1°C
33°C
13
10
16
37~depending on outdoor unit, step: 1°C
55°C
15~37°C, step: 1°C
25°C
18~22°C, step: 1°C
22°C
5~18°C, step: 1°C
5°C
1~4°C, step: 1°C
1°C
15~37°C, step: 1°C
25°C
37~depending on outdoor unit, step: 1°C
55°C
5~18°C, step: 1°C
5°C
18~22°C, step: 1°C
22°C
3~10°C, step: 1°C
5°C
3~10°C, step: 1°C
5°C
0: Quick
1: Slow
1~6°C, step: 0,5°C
1 °C
0~8, step:1
0 : 100%
1~4 : 80~50%
5~8 : 80~50%
6
6
0
0 (*5)
3 (*6)
7/9
Installer setting at variance with
default value
Date
Value
4P383508-1 - 2015.01