HAKO Scrubmaster B310 R CL/TB 1020 Instruction Manual page 62

Hide thumbs Also See for Scrubmaster B310 R CL/TB 1020:
Table of Contents

Advertisement

Operation
The following error codes are only valid for 7580.41:
Error code
2.2.5.1
Rotary brush remains stopped
because the thermostatic
switch has been tripped.
2.2.6.1
Rotary brush remains stopped
because the anti-blocking sys-
tem has been tripped.
2.2.6.2
Rotary brush holding attach-
ment has been switched off
because the anti-blocking sys-
tem has been tripped.
2.3.6.1
The left side brush (viewed to
the front of the vehicle) stops
because the anti-blocking sys-
tem has been tripped.
2.3.6.2
The right side brush (viewed
to the front of the vehicle)
stops because the anti-block-
ing system has been tripped.
62
Fault
The motor has overheated. For-
eign bodies (e.g. tape or such)
possibly block the rotary brush.
Foreign bodies (e.g. tape or
such) block the rotary brush.
Foreign bodies (e.g. tape or
such) between the rotary brush
Foreign bodies (e.g. tape or
such) block the side brush.
Foreign bodies (e.g. tape or
such) block the side brush.
Cause
• Check the rotary brush for foreign bod-
• Allow the motor to cool down.
• If the problem reoccurs, determine the
Check the rotary brush for foreign bodies
and remove them, as necessary.
Check the rotary brush holding attachment
for foreign bodies, remove them as neces-
and machine.
sary.
Check the side brushes for foreign bodies
and remove them, as necessary.
Check the side brushes for foreign bodies
and remove them, as necessary.
Solution
ies and remove them, as necessary.
cause of overheating; contact anautho-
rized Hako service center, if necessary.

Hide quick links: