Operation
In the case of the Scrubmas-
ter B310 R CL without the pre-
sweep/vacuum unit (7580.42),
the corresponding buttons
have no function.
Button for agitating device
(Fig. 20/2)
This button serves to switch
an agitation process on and
off, whereby the filter system
on the pre-sweep/vacuum
unit is cleared of the dust attached. Af-
ter pressing the button, an agitation pro-
cess runs for approx. 6 seconds in in-
tervals; press the button again to end
the process prematurely. Alternatively
to pressing the button, you can turn the
key switch to position 0 or 1 (RESET).
46
Button for extractor fan
(Fig. 20/3)
This button serves to switch
the extractor fan of the filter
system on and off. The filter
system belongs to the op-
tional pre-sweep/vacuum unit.
Button to switch pre-
sweep/vacuum unit on/off
(Fig. 20/4)
This button is used to switch
the pre-sweep/vacuum unit
on and off.
Button for side scrubbing
unit
(Fig. 20/5) This button is
used to activate the side
scrubbing unit. After press-
ing the button, the side
scrubbing brush starts or stops rotating
and the side scrubbing brush is lowered
or raised accordingly. When the side
scrubbing unit is activated, the green
control lamp lights up.
The side scrubbing unit is an optional
accessory. If it is not installed, the but-
ton has no function.
The side scrubbing unit can
only be switched on when the
circular brushes are also
switched on.