7. Troubleshooting

Following are a few common problems that may occur during operation.
Here are some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link
properly.
2. If the DMX LED is on and no response to the channel, check the address
settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or
on PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that
may cause damage or interference to DMX interface circuit.
C. Some units don't respond to the easy controller
1. You may have a break in the DMX cabling.
2. Check the LED for the response of the master/ slave mode signal.
D. No response to the sound
1. Make sure the unit does not receive DMX signal.
2. Check if the sound sensitively is too low.
E. One of the channels is not working well
1. The cable connected to the PCB may be broken.

8. Fixture Cleaning

The cleaning of internal and external optical lenses and/or mirrors must be carried
out periodically to optimize light output. Cleaning frequency depends on the
environment in which the fixture operates: damp, smoky or particularly dirty
surrounding can cause greater accumulation of dirt on the unit's optics.
 Clean with soft cloth using normal glass cleaning fluid.
18-
 Always dry the parts carefully.
 Clean the external optics at least every 20 days. Clean the internal optics at least
every 30/60 days.
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55103-1:199601-2; EN55103-2:1996;
EN61000-3-2:2000+A2:2005;
EN61000-3-3:1995+A1:2001+A2:2005.
Harmonized Standard
IEC 60598-1:2003+ corrigendum 2004
Part 1:General requirements and test
Following the provisions of the low voltage directive 73/23/EEC and
93/68/EEC
Innovation, Quality, Performance
&
EN 60598-1: 2004