Datadump - Johannus symphonica 450 User Manual

Hide thumbs Also See for symphonica 450:
Table of Contents

Advertisement

1.
Press the MENU piston.
Use the - and + pistons to select the Crescendo function on the display.
2.
3.
Press the SET piston. The first step of the crescendo pedal appears on the
display.
4.
Use the - and + pistons to select the step which has to be changed.
5.
Change the registration and press the SET piston to save the new registration
in the memory of the organ.
6.
Repeat steps 4 and 5 if more crescendo pedal steps has to be changed.
7.
Press the MENU piston twice to exit the Johannus Menu.
5.3

Datadump

The Datadump function sends several settings from the organ to a storage medium (the
Johannus MIDI Sequencer+, for example) through the MIDI SEQ output. See § 3.4 External
connections.
The settings to send are: the content of all capture memory locations and all settings which
can be set via the Johannus Menu, except Key Volumes. Key Volume settings are a part of the
intonation data. These data can be received with the optional Johannus Intonat software.
a. Sending data from the organ
1.
Press the MENU piston.
Use the - and + pistons to select the Datadump function on the display.
2.
Press the SET piston. The Press SET to send data text appears on
3.
the display.
4.
Make sure the desired storage medium, the Johannus MIDI Sequencer+ for
example, is properly connected.
Press the SET piston. When data is being sent, Sending data appears on
5.
the display. Sending data will take some time.
Do not use the organ when the Sending data... text is on the display.
6.
If the data dump is complete, the main menu appears on the display.
7.
Press the MENU piston to exit the Johannus Menu.
b. Uploading data to the organ
Receiving a data file has no relation to the Johannus Menu and can be done
on every moment the organ is switched on, except when playing a Demo
Song.
Make sure to upload only data files which are recorded from the
instrument concerned. Uploading a data file from another instrument may
jeopardize the functioning of your instrument.
1.
Make sure the storage medium, the Johannus MIDI Sequencer+ for example,
with a previous recorded data file is properly connected.
2.
Start sending the data file on the sequencer. A message that a data file is
being received appears on the display of the organ.
3.
When the upload is completed the main screen of the display appears
automatically.