Follow the instructions and precautionary measures in this user manual. Keep this user manual with the organ. The organ may only be opened by a technician authorized by Johannus Orgelbouw b.v. The organ contains static-sensitive components. The warranty is void if the organ is opened by a non-authorized person.
2 INSTALLATION Installation and connection 2.1.1 Ecclesia T-250 Installing loudspeakers: The external loudspeakers have to be installed by an authorized Johannus installer. Installing console: Position the organ on a stable, horizontal surface. Lean the organ slightly backward. Slide the pedal board (D) against the organ.
2.1.2 Ecclesia D-350 Installing loudspeakers: The external loudspeakers have to be installed by an authorized Johannus installer. Installing console: Position the organ on a stable, horizontal surface. Lean the organ slightly backward. Slide the pedal board (D) against the organ.
2.1.3 Ecclesia D-450 Installing loudspeakers: The external loudspeakers have to be installed by an authorized Johannus installer. Installing console: Position the organ on a stable, horizontal surface. Lean the organ slightly backward. Slide the pedal board (D) against the organ.
Starting the control functions and the settings will take some time. The lights of the 0 piston and the as standard set functions lit up. The settings appear on the display. User Manual Ecclesia T-250 / D-350 / D-450...
3 DESCRIPTION OF THE ORGAN Overview of the components 3.1.1 Ecclesia T-250 A Roll cover lock (behind music desk) B Music desk C Roll cover D Organ bench E Swell pedal Crescendo pedal G Pedal board User Manual Ecclesia T-250 / D-350 / D-450...
3.1.2 Ecclesia D-350 A Roll cover lock (behind music desk) B Adjustable music desk C Roll cover D Organ bench E Swell pedal Crescendo pedal G Pedal board User Manual Ecclesia T-250 / D-350 / D-450...
3.1.3 Ecclesia D-450 A Roll cover lock (behind music desk) B Roll cover C Folding music desk D Organ bench E Swell pedal Crescendo pedal G Pedal board User Manual Ecclesia T-250 / D-350 / D-450...
SEQ- and SEQ+ pistons Pre-programmed memory locations S/S: All Swells to Swell 0: Recall / Reset MIDI stops RO: Reeds Off Intonation styles CH: Chorus AA Orchestral solo voices MB: Manual Bass AB Orchestral voices User Manual Ecclesia T-250 / D-350 / D-450...
Pre-programmed memory locations S/S: All Swells to Swell 0: Recall / Reset AA MIDI stops RO: Reeds Off AB Intonation styles CH: Chorus AC Orchestral solo voices MB: Manual Bass AD Orchestral voices User Manual Ecclesia T-250 / D-350 / D-450...
Pre-programmed memory locations S/S: All Swells to Swell 0: Recall / Reset AA MIDI stops RO: Reeds Off AB Intonation styles CH: Chorus AC Orchestral solo voices MB: Manual Bass AD Orchestral voices User Manual Ecclesia T-250 / D-350 / D-450...
PHONES: This connection for a (stereo) headphone is suited for a headphone with an impedance of 30 Ω or more (see headphone specifications). When the headphone is used, the loudspeakers of the organ are switched off automatically. User Manual Ecclesia T-250 / D-350 / D-450...
4 OPERATION General volume The general volume of the organ can be adjusted with use of the Johannus Menu. See § 5.4 General Volume. Expression pedals In the standard version the organ has two expression pedals. One is configured as a swell pedal for the Swell, and one is configured as a crescendo pedal.
Solo- and orchestral voices are standard playable from a factory defined manual. This can be changed via Quick Access, see § 4.11.3 Keyboard assignment Orchestrals, and via the Johannus Menu, see § 5.8 Orchestrals. Couplers Manual couplers: CHOIR - GREAT (Ecclesia D-350/D-450) Fully couples all keys of the Choir to the Great.
SWELL - GREAT because this overrules the solo function of the Cantus Firmus. Accessories Keyboard Transfer (KT): Ecclesia T-250: Keyboard Transfer is a function to switch the manuals of the Great and the Swell. When Keyboard Transfer is active manual 1 is the Swell manual and manual 2 is the Great manual.
Through use of the SEQ- and SEQ+ pistons previous or next memory locations can be selected in steps of one. The lighted memory location piston and the memory level shown in the display indicate the selected location. User Manual Ecclesia T-250 / D-350 / D-450...
If the crescendo pedal is set as additional swell pedal, all functions of the original crescendo pedal are deactivated. 4.11 Quick Access Quick Access is a function to quickly access certain function of the organ. User Manual Ecclesia T-250 / D-350 / D-450...
Panflute. The actual assignment appears on the display. Press a key of the manual or the pedal on which the solo- or orchestral voice has to be assigned or press the SET- or MENU-piston to cancel. User Manual Ecclesia T-250 / D-350 / D-450...
Press the MENU piston 2x to exit the Johannus Menu. Datadump The Datadump function sends several settings from the organ to a storage medium (the Johannus Sequencer+, for example) through the MIDI SEQ output. See § 3.4 External connections. User Manual Ecclesia T-250 / D-350 / D-450...
The settings to sent are: the content of all capture memory locations and all settings which can be set via the Johannus Menu, except Key Volumes. Key Volume settings are a part of the intonation data. These data can be received with the optional Johannus Intonat software.
10. Press the MENU piston to return to the Expression Pedals menu. 11. If necessary, repeat steps 4 to 10 for another expression pedal. 12. Press the MENU piston 2x to exit the Johannus Menu. General Volume The General Volume function sets the general volume of the organ.
10. Press the SET piston to save the change. The display requests confirmation. Use the - and + pistons to select No or Yes. 11. Press the SET piston to confirm. 12. Press the MENU piston to return to the Key Volume menu. User Manual Ecclesia T-250 / D-350 / D-450...
Page 27
16. Use the - and + pistons to select Yes. Press the SET piston for confirmation. 17. Press the MENU piston 3x to exit the Johannus Menu. More key volumes can be changed by pressing another key or by selecting another stop.
12. Press the SET piston. The selected configuration is now stored in memory. The pointer jumps back to the MIDI channel location. 13. Press the MENU piston 2x to exit the Johannus Menu. Orchestrals The Orchestral menu is only available if the organ is equipped with the optional Premium or Platinum Voice Package.
Press a key on the manual or pedal on which the solo- or orchestral voice has to be assigned. The new assignment appears on the display. Press the MENU piston 3x to exit the Johannus Menu. Reset Procedures The Reset Procedures function can be used to reset a number of settings to the factory settings.
Use the - and + pistons to select the desired setting. Press the SET piston to confirm and to return to the Startup Settings menu. Press the MENU piston 2x to exit the Johannus Menu. b. Default Intonation Startup Setting Default Intonation determines which intonation style is selected at startup of the organ.
Page 31
Use the - and + pistons to select the desired intonation style. Press the SET piston to confirm and to return to the Startup Settings menu. Press the MENU piston 2x to exit the Johannus Menu. c. Headphone / Aux-Out Startup Setting Headphone / Aux-Out determines the volume level of the headphone / Aux-output at startup of the organ.
Mode function. 13. Press the SET piston to confirm and to return to the Startup Settings menu. 14. Pres the MENU piston 2x to exit the Johannus Menu. 5.12 Temperaments The Temperaments function sets the temperament. The set temperament can be read on the display behind the Temp: text.
Use the - and + pistons to select the desired pitch of the pressed key. If necessary repeat steps 6 and 7 for another key of the middle octave. Press the MENU piston 2x to exit the Johannus Menu. Using the reset procedure Cust. Temperament def. the Custom Temperament can be reset to equal temperament.
Use the - and + pistons to select the Version function on the display. Press the SET piston. The data of the software of the organ appears on the display. Press the MENU piston 2x to exit the Johannus Menu. User Manual Ecclesia T-250 / D-350 / D-450...
‘Automatic’ or ‘Velocity’. If the operation of the manual keys is set to ‘High’ or ‘Low’ the solo- or orchestral voice sounds always with an average sound and volume. See § 5.5 Keyboard Config for setting the operation of the manual keys. User Manual Ecclesia T-250 / D-350 / D-450...
Page 36
- bright sound Details: Tuba Compass: C - f’’’ Use with couplers: normal Velocity behavior: soft touch: - low volume - mellow sound strong touch: - strong volume - bright sound Details: User Manual Ecclesia T-250 / D-350 / D-450...
Page 37
- low volume - mellow sound - mild chiff strong touch: - strong volume - bright sound - more chiff Details: - fourfold - sound divided over organ and surround loudspeakers User Manual Ecclesia T-250 / D-350 / D-450...
Page 38
Use with couplers: normal Velocity behavior: Details: Special Stops When using the harpsichord, special Mode: settings for reverb and tweeters are enabled. See § 5.11 Startup Settings, sub d: Special Stops Mode. User Manual Ecclesia T-250 / D-350 / D-450...
Page 39
The keys C - e of the pedal board remain their normal organ function. The switch to sustain pedal will be indicated shortly on the display when the piano is activated. User Manual Ecclesia T-250 / D-350 / D-450...
Page 40
The keys C - e of the pedal board remain their normal organ function. The switch to sustain pedal will be indicated shortly on the display when the piano is activated. User Manual Ecclesia T-250 / D-350 / D-450...
Harp, Piano I and Piano Extended cannot be played simultaneously. Gospel Organ I and Gospel Organ II cannot be played simultaneously. If one of these orchestral voices is activated, the corresponding orchestral voice(s) will be disabled automatically. User Manual Ecclesia T-250 / D-350 / D-450...
The conditions are specified in the warranty certificate. The warranty is void if changes or repairs are made to the organ by persons or organizations that are not authorized by Johannus Orgelbouw b.v. User Manual Ecclesia T-250 / D-350 / D-450...
: Active Sense : Reset Notes Depends on number of divisions Mode 1: OMNY ON, POLY Mode 2: OMNY ON, MONO Y=YES Mode 3: OMNY OFF, POLY Mode 4: OMNY OFF, MONO N=NO User Manual Ecclesia T-250 / D-350 / D-450...
Only the value of the 8th byte varies. This is the ‘sys ex message’ that Johannus generally uses: F0 00 4A 4F 48 41 53 XX F7 (hexadecimal). The ‘sys ex messages’ described below only indicates the value of the 8th byte (XX) and the output from which it is transmitted.
Page 45
When a piston is pressed, a sys ex code is transmitted with the value of the piston that is pressed (for example PP = 00 P = 01) through the MIDI MOD. output. These sys ex codes are only important when the Johannus sound module CSM 128 is connected to your instrument.
Page 46
User Manual Ecclesia T-250 / D-350 / D-450...
Page 47
User Manual Ecclesia T-250 / D-350 / D-450...
Page 48
User Manual Ecclesia T-250 / D-350 / D-450...
Need help?
Do you have a question about the Ecclesia T-250 and is the answer not in the manual?
Questions and answers