Sounder Volume Levels (At 1M); Fuses; Electrical Safety; Other - Eaton menvier300 Installation Manual

Hide thumbs Also See for menvier300:
Table of Contents

Advertisement

Menvier300
LS 1 & 2
Min impedance 16 Ohm per
(loudspeaker)
output, current consumption =
280mA in alarm.
Expander:
Open collector transistor,
Outputs
+12VDC when inactive, 0V
when active. 500mA max.
Note: The current is limited by
the amount available from the
power supply driving the
expander.
KEY-KPZ01
Open collector transistor,
Outputs
+12VDC when inactive, 0V
when active, 500mA max.

Sounder Volume Levels (at 1m)

i-kp01 (at max volume)
Expander sounders
Expander 16 Ohm loudspeaker

Fuses

The control unit has a replaceable T500mA mains
fuse.

Electrical Safety

Conforms to EN60950-1.

Other

If you wish to connect the Menvier300 control unit
to a PC using either the Ethernet or the USB port
then make sure that the cables have the following
specifications:
Ethernet
Cat5e patch cable, straight or
crossed, RJ45 male plugs at
each end, suitable for
10/100Base-T.
USB
Mini-B plug for control unit end,
USB-A for PC end. Max length
3m.

Radio Expander and Keypads

Radio
Operating frequency
868.6625MHz Narrowband.
EN 300 220-3.
EN 300 330-2
Transmitter
The range of the transmitters
range
compatible with this control unit
depends on the environment in
which they are installed. As a
guideline, most transmitters will
work up 200m range in free
space conditions.

Compliance Statements

The Menvier300 is compliant with EN50130-5
environmental class II.
The Menvier300 is suitable for use in systems
designed to comply with PD 6662: 2010 at grade
3.
When installed correctly the Menvier300 is
capable of compliance with EN50131 at Grade 3.
To maintain Grade 3 the Menvier300 must be
fitted with a communicator of level ATS4 or above.
When fitted with radio devices the Menvier300 is
capable of compliance with EN50131 at Grade 2.
The i-sd02 is compliant with EN50136-1 as an
70dB
ATS2 communicator.
70dB
93dB
The i-sd02 may be used as a supplementary
communicator at Grade 3.
At Grade 2 the i-sd02 provides a compliant
communicator for the Menvier300 provided that:
a) It is installed in accordance with the
installation instructions.
b) The connected PSTN is functioning normally.
When fitted with an i-sd02 this product provides
options A, B and C at Grade 2 as noted in Table
10 of EN50131-1:2006+A1:2009.
If the installer selects a non-compliant
configuration then they must remove or adjust
compliance labelling
Third party testing carried out by Anpi.

Compatible Equipment

HUD

705rEUR-00
706rEUR-00
710rEUR-00
726rEUR-50
726rEUR-60

Detectors

713rEUR-00
714rEUR-00
720rEUR-00
734rEUR-00/01
734rEUR-05/06
738rEUR-00/04
739rEUR-50
Technical Specification
Two button HUD (single
channel, top button is
disabled)
Two button HUD/tilt switch
transmitter
Two button HUD
Long range hand held HUD
Short range hand held HUD
Pet tolerant PIR
PIR Transmitter (Small case)
Smoke Detector Transmitter
CC/FSL Door Contact
Transmitter (white)
CC/FSL Door Contact
Transmitter (brown)
Spyder shock sensor
(white/brown)
Sentrol glass break detector
Page 35