Electromagnetic Compatibility; Outputs; Sounder Volume Levels (At 1M); Fuses - Eaton i-on1000EX Installation Manual

Hide thumbs Also See for i-on1000EX:
Table of Contents

Advertisement

i-on1000EX
Wired Expander
requirement
Radio Expander
requirement
Battery charging
requirement:
Plug-on
Communicator power
requirement:
Plug-on
Communicator power
requirement
Plug-by
Communicator pins
require:
10 FSL zones
5x4-wire CCL zones
12V Bus output
voltage range :
12V Aux output
voltage range:
12V Bell output
voltage range
14.4V output voltage
range:
Max p-to-p ripple
voltage:
Standby Battery:
'Low battery' fault at:
Aux power output fault
at:
Deep discharge
protection at:
Overvoltage protection
trigger voltage
Serviceable
components:
Standby time:
Electromagnetic
Compatibility
Immunity
Conforms to EN50130-4.
Emissions
Conforms to EN61000-6-3.

Outputs

Panel:
Voltage free, single pole relay
O/P 1 - 4
contacts rated 24VDC @ 1A.
Panel:
Open collector transistor,
O/P 5 - 8
+12VDC when inactive, 0V
when active. 500mA max.
Plug-by O/P 1-
Open collector transistor
16
+12VDC when inactive, 0V
when active, 50mA max.
20mA max quiescent.
300mA in alarm if
sounder connected.
40mA max quiescent
320mA in alarm if
sounder connected.
750mA per battery
(recharge within 24 hrs)
i-sd02, i-dig02:
20mA quiescent
50mA max
i-gsm02:
150mA quiescent
and max.
5mA each when active.
20mA
30mA
10±0.5V to 13.8V
10±0.5V to 13.8V
10±0.5V to 13.8V
10±0.5V to 14.7V
0.5V
12V, 17Ah sealed lead
acid, 2 off (not supplied).
< 12V
< 9V
10±0.5V
15.6±1.0V
Mains fuse: 500mA (T)
See "Power Availability"
on page 10.
Technical Specification
LS 1 & 2
Min impedance 16 Ohm per
(loudspeaker)
output, current consumption =
280mA in alarm.
Expander:
Open collector transistor,
Outputs
+12VDC when inactive, 0V
when active. 500mA max.
Note: The current is limited by
the amount available from the
power supply driving the
expander.
KEY-KPZ01
Open collector transistor,
Outputs
+12VDC when inactive, 0V
when active, 500mA max.

Sounder Volume Levels (at 1m)

i-kp01 (at max volume)
Expander sounders
Expander 16 Ohm loudspeaker

Fuses

The control unit has a replaceable T500mA mains
fuse.

Electrical Safety

Conforms to EN60950-1.

Other

If you wish to connect the i-on1000EX control unit
to a PC using either the Ethernet or the USB port,
make sure that the cables have the following
specifications:
Ethernet
Cat5e patch cable, straight or
crossed, RJ45 male plugs at
each end, suitable for
10/100Base-T.
USB
Mini-B plug for control unit end,
USB-A for PC end. Max length
3m.

Radio Expander and Keypads

Radio
Operating frequency
868.6625MHz Narrowband.
EN 300 220-3.
EN 300 330-2
Transmitter
The range of the transmitters
range
compatible with this control unit
depends on the environment in
which they are installed. As a
guideline, most transmitters will
work up 200m range in free
space conditions.
70dB
70dB
93dB