Selecting DHW heating
Start optimisation for cylinder heating
Press the following keys:
1. "Device settings"
2. "Programming"
3. "DHW"
4. y/x for "Start optimisa-
tion"
Stop optimisation for cylinder heating
The stop optimisation ensures that the DHW cylinder is fully heated until the end of
operation in standard mode.
Note
This function is only enabled if switching
times have been set for the DHW cylin-
der (see page 30).
DHW
Set DHW temp.
Switching times DHW
DHW with e heating
Start optimisation
Stop optimisation
Pasteurisation
Set temp. 2
YES
Press the following keys:
1. "Device settings"
36
5. "YES/NO" to activate / deactivate
6. "BACK"
2. "Programming"
3. "DHW"
4. y/x for "Stop optimisa-
[1/0]
:
50.0
:
T
5. "YES/NO" to activate / deactivate
Yes
:
:
No
:
No
6. "BACK"
:
Yes
:
60.0
Back
(cont.)
the function
to confirm and exit the
menu
tion"
the function
to confirm and exit the
menu