Setting Switching Times Of The Auxiliary Output (E.g. Dhw Circulation Pump) - Viessmann vitocal 300-g Operating Instructions Manual

Compact heat pump with electric drive, type bw/bwc and ww/wwc
Table of Contents

Advertisement

Selecting constant DHW heating
The operating mode for the selected time
period (15 min block, top left) is dis-
played by bar height and number (1, 2, 3
or 4).
■ In "TOP" operating mode, a reduced
volume of DHW is made available.
Only a part of the DHW cylinder is
heated to the "Set DHW temp." tem-
perature.
■ In "STANDARD" operating mode, the
entire DHW volume in the DHW cylin-
der is heated to the "Set DHW
temp." temperature.
■ In "STANDARD" and "TEMP. 2"
operating modes, the lower cylinder
temperature sensor is used as a shut-
down criterion (if installed).
■ In "TEMP. 2" operating mode, "Set
temp. 2" is selected as the constant
DHW temperature. The "Set temp.
2" is higher than the "Set DHW
temp." temperature. This is connec-
ted to "Pasteurisation" (see
page 34).
Press the following keys:
1. "Device settings"
2. "Programming"
Setting switching times of the auxiliary output (e.g. DHW circu-
lation pump)
Your heating contractor can connect a DHW circulation pump to the auxiliary output
on your control unit. Here, setting switching times effects a changeover between the
operating modes "OFF", "30/5 CYCLE", "15/5 CYCLE" and "ON".
Selecting DHW heating
(cont.)
3. "DHW"
4. y/x for "Switching times
DHW"
5. ?
to open the "Switching
times DHW" menu
6. "DAY"
for the required day or
part of the week
7. "VALUE"
for the required operat-
ing mode
8. >
for the time (time top
left / position of arrow
bottom) from which the
operating mode should
be changed.
9. "SET"
for the required time
period (min. 15 min)
10. Proceed as described in points 6 to
9 for the setting of further switching
times.
11. "OK"
to confirm and exit the
menu
31