Bypass Groups; Arming Errors And Exit Faults; Arming Errors - DSC Neo HS2016 User Manual

Power series
Hide thumbs Also See for Neo HS2016:
Table of Contents

Advertisement

Chapter 3

3.8 Bypass Groups

Program frequently bypassed zones into the system as a bypass group. Using bypass groups avoids individually bypassing each zone.
One bypass group can be programmed per partition.
Note: This feature is not to be used in UL listed installations.
To Program a Bypass Group
1.
Press [*] to enter the function menu.
2.
Press [*] or [1]. If required enter your [access code].
3.
Enter the [3 digit zone #] of all zones you want bypassed
OR
Scroll to and press [*] to indicate all zones you want bypassed.
4.
Press [9][9][5] to program the bypass group with the currently bypassed zones
OR
Scroll to Bypass Options using the
Group and press [*].
5.
The Bypass Group is now programmed. The keypad will beep three times.
6.
To exit bypassing mode and return to the Ready state, press .
To Load a Bypass Group
1.
Press [*] to enter the function menu.
2.
Press [*] or [1]. If required enter your [access code].
 
3.
Press or [9][9][1]. If required enter your [access code].
OR
Scroll to Bypass Options using the
Group and press [*].
4.
The group of zones are now bypassed. The following message briefly displays.
5.
To exit bypassing mode and return to the Ready state, press [*].
6.
If using an LED or ICN series keypad, the will light and the bypassed zones #s will
be shown. If the system is ready to arm the Ready indicator will be lit. When arming
the system the following message briefly displays.

3.9 Arming Errors and Exit Faults

The PowerSeries Neo audibly notifies you of any errors when you are attempting to arm the system or exit the premises.

3.9.1 Arming Errors

An error tone (long beep) sounds if the system is unable to arm. Arming errors occur if:
The system is not ready to arm (i.e., sensors are open).
l
An incorrect user code is entered.
l
A trouble is present and has not been viewed by the user. This operation must be enabled by the installer.
l
To Correct an Arming Error
1.
Ensure all sensors are secure. Your keypad will identify all open zones.
2.
If the trouble light is on, enter [*][2] and enter [99] or scroll to the Acknowledge All Troubles prompt and press [*], if your
installer has configured your system to impede arming when a trouble is present.
3.
Try arming the system again. For details on arming the system, see one of the previous arming procedures.
4.
If errors persist contact your installer.
keys and press [*]. Scroll to Prg Bypass
keys and press [*]. Scroll to Bypass
- 13 -
LCD Display
Press (*) for <>
Zone Bypass
Scroll to <>
Bypass Zones
Upstrs H Wdw <>
B
Press (*) for <>
Prg Bypass Group
Bypass Group
Programmed
System is
Ready to Arm
LCD Display
Press (*) for <>
Zone Bypass
Scroll to <>
Bypass Zones
 
Press (*) for <>
Bypass Group
Bypass Group
Zones Bypassed
 
* Warning *
Bypass Active

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hs2128Hs2032Hs2064

Table of Contents