Chapter 3
3.
Press [0][0][0]
OR
Scroll to Clear Bypasses using the
will now be open.
4.
To exit bypassing mode press [*].

3.9 Bypass Groups

Program frequently bypassed zones into the system as a bypass group. Using bypass groups avoids individually bypassing each zone.
One bypass group can be programmed per partition.
Note: This feature is not to be used in UL listed installations.
 
To Program a Bypass Group
1.
Press [*] to enter the function menu.
2.
Press [*] or [1]. If required enter your [access code].
3.
Enter the [3 digit zone #] of all zones you want bypassed
OR
Scroll to and press [*] to indicate all zones you want bypassed.
4.
Press [9][9][5] to program the bypass group with the currently bypassed zones
OR
Scroll to Bypass Options using the
Group and press [*].
5.
The Bypass Group is now programmed. The keypad will beep three times.
6.
To exit bypassing mode and return to the Ready state, press .
To Load a Bypass Group
1.
Press [*] to enter the function menu.
2.
Press [*] or [1]. If required enter your [access code].
 
3.
Press or [9][9][1]. If required enter your [access code].
OR
Scroll to Bypass Options using the
Group and press [*].
4.
The group of zones are now bypassed. The following message briefly displays.
5.
To exit bypassing mode and return to the Ready state, press [*].
6.
If using an LED or ICN series keypad, the will light and the bypassed zones #s will
be shown. If the system is ready to set the Ready indicator will be lit. When setting
the system the following message briefly displays.

3.10 Setting Errors and Exit Faults

The PowerSeries Neo audibly notifies you of any errors when you are attempting to set the system or exit the premises.

3.10.1 Setting Errors

An error tone (long beep) sounds if the system is unable to set. Setting errors occur if:
The system is not ready to set (i.e., sensors are open).
l
An incorrect user code is entered.
l
A trouble is present and has not been viewed by the user. This operation must be enabled by the installer.
l
keys and press [*]. All Bypassed zones
keys and press [*]. Scroll to Prg Bypass
keys and press [*]. Scroll to Bypass
- 12 -
Press (*) for <>
Clear Bypasses
then
Bypass Cleared
Zones Unbypassed
 
LCD Display
Press (*) for <>
Zone Bypass
Scroll to <>
Bypass Zones
Upstrs H Wdw <>
B
Press (*) for <>
Prg Bypass Group
Bypass Group
Programmed
System is
Ready to Arm
LCD Display
Press (*) for <>
Zone Bypass
Scroll to <>
Bypass Zones
 
Press (*) for <>
Bypass Group
Bypass Group
Zones Bypassed
 
* Warning *
Bypass Active

Advertisement