Permissible Operating Conditions At The Pocket; Probe Mountings 20 And 22 - JUMO ATH-EXx Operating Instructions Manual

Explosion-protected surface-mounted thermostat
Table of Contents

Advertisement

3.5

Permissible operating conditions at the pocket

3.5.1 Probe mountings 20 and 22

3.5.1.1
Steel pockets
Materials
Loading
The values given below refer to the maximum loading on the probe mounting
concerned. The maximum pressure which can be sealed depends on the
mounting conditions and may possibly be lower.
Tube:
Weld-in nipple:
Temperature
100°C
150°C
200°C
300°C
400°C
450°C
With operating temperatures above 420°C, the permissible operating time is
limited to 200,000 hours. TRD 508 must be observed in this respect.
St 35.8 I
16 Mo 3 (no turned groove)
Tube diameter
8 x 0.75 mm or
conical
max. permissible
pressure
89 bar
83 bar
78 bar
59 bar
46 bar
24 bar
3 Mounting
10 x 0.75 mm
15 x 0.75 mm
max. permissi-
max. permissi-
ble pressure
ble pressure
72 bar
67 bar
63 bar
47 bar
37 bar
19 bar
48 bar
45 bar
42 bar
32 bar
25 bar
13 bar
11

Advertisement

Table of Contents
loading