3.4

Permissible loading on the pocket

3.4.1 Pockets U, US, E and ES

A
3.4.1.1
Steel pockets U, US, E and ES
Materials
Loading
The values given below refer to the maximum loading on the probe mounting
concerned. The maximum pressure that can be sealed depends on the
installation conditions and may possibly be lower.
Tube:
Screw-in nipple up to 300°C: 9 SMnPb28 K
Screw-in nipple up to 450°C: 16 Mo 3 (turned groove)
Weld-in nipple:
Temperature
100°C
150°C
200°C
300°C
350°C
St 35.8 I
16 Mo 3 (no turned groove)
Tube diameter D
8 x 0.75 mm
10 x 0.75 mm
or conical
Max. permissible pressure
89 bar
83 bar
78 bar
59 bar
50 bar
3 Mounting
15 x 0.75 mm
72 bar
67 bar
63 bar
47 bar
40 bar
48
45
42
32
27
13