IBM 6151 Maintenance And Service Manual page 189

Table of Contents

Advertisement

Step 13
You are here because the system is failing only when a diagnostic
checkout other than the System Checkout is run. The following
FRUs are required
to
select a checkout procedure:
The system board
The processor board
If installed, the memory expansion option in slot C
An adapter for the diskette drive
An IBM High Capacity Diskette Drive
A display adapter
A display
The cables for the diskette drive
The power supply
The cooling fan
A keyboard.
When the FRUs listed above are installed, the following selections
display on the DIAGNOSTIC SELECTION menu:
System Checkout
Display Checkout
Diskette Drive Checkout
Checkout for the fixed-disk and diskette drive adapter
Keyboard Checkout.
Step 13 continues on the next page.
(6/88) Problem Isolation Charts