Moxa Technologies ToughNet TN-5508 Series Hardware Installation Manual
Moxa Technologies ToughNet TN-5508 Series Hardware Installation Manual

Moxa Technologies ToughNet TN-5508 Series Hardware Installation Manual

M12 managed 8/8+2g-port

Advertisement

Quick Links

Moxa ToughNet Switch
TN-5508/5510 Series
Layer 2 M12 managed 8/8+2G-port Ethernet switches

Hardware Installation Guide

First Edition, October 2009
© 2009 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
P/N: 1802055080011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ToughNet TN-5508 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Moxa Technologies ToughNet TN-5508 Series

  • Page 1: Hardware Installation Guide

    Moxa ToughNet Switch TN-5508/5510 Series Layer 2 M12 managed 8/8+2G-port Ethernet switches Hardware Installation Guide First Edition, October 2009 © 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. P/N: 1802055080011...
  • Page 2: Package Checklist

    Overview The ToughNet TN-5508/5510 series M12 managed Ethernet switches are designed for industrial applications in harsh environments. The TN series switches use M12 and other circular connectors to ensure tight, robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock. The wide selection of 12/24/36/48 VDC, 72/96/110 VDC, or 110/220 VDC/VAC dual redundant power supplies increases the reliability of your communications.
  • Page 3: Recommended Optional Accessories

    High Performance Network Switching Technology IPv6 Ready logo awarded (IPv6 Logo Committee certified). IEEE 1588 PTP (Precision Time Protocol) for precise time synchronization of networks. DHCP Option 82 for IP address assignment with different policies. Modbus/TCP industrial Ethernet protocol. Turbo Ring, Turbo Chain,and RSTP/STP (IEEE802.1w/D). IGMP Snooping and GMRP for filtering multicast traffic from industrial Ethernet protocols.
  • Page 4 DK-DC50131: DIN-Rail mounting kit, 50 x 131 mm. A-PLG-WPRJ-02: Field-installable circular connector kit for RJ45 twisted-pair cable, IP67-rated. TN-5508 Panel Layouts Top View 8 9 10 11 12 Front View Botton View Rear View 3 Rotary switches and protective cover with Model name. Screw holes for panel mounting kit.
  • Page 5 Power input voltage range indication. Power input port (male 5-pin shielded M23 connector). PWR1 LED: for power input 1. PWR2 LED: for power input 2. 10. FAULT LED. 11. MSTR/HEAD LED: for ring master or chain head. 12. CPLR/TAIL LED: for ring coupler or chain tail. 13.
  • Page 6 TN-5510 Panel Layouts Top View 8 9 10 11 12 Front View Botton View Rear View 3 Rotary switches and protective cover with Model name. Screw holes for panel mounting kit. Console port. Grounding screw. Relay output port. Power input voltage range indication. Power input port (male 5-pin shielded M23 connector).
  • Page 7 PWR1 LED: for power input 1. PWR2 LED: for power input 2. 10. FAULT LED. 11. MSTR/HEAD LED: for ring master or chain head. 12. CPLR/TAIL LED: for ring coupler or chain tail. 13. TP port’s 10/100 Mbps LED. 14. 10/100BaseT(X) port (female 4-pin shielded M12 connector with D coding).
  • Page 8: Mounting Dimensions (Unit = Mm)

    Mounting Dimensions (unit = mm) TN-5508 Series — 7 —...
  • Page 9 TN-5510 Series — 8 —...
  • Page 10: Panel/Wall Mounting

    Panel/Wall Mounting STEP 1: Mounting the TN-5508/5510 to a wall requires 4 screws. Use the ToughNet switch as a guide to mark the correct positions of the 4 screws. STEP 2: Use the 4 screws in the panel mounting kit. If you 6.0 - 7.0 mm would like to use your own screws, make sure the screw head is between 6.0 mm and 7.0 mm in...
  • Page 11: Wiring Requirements

    STEP 2: If the spring-loaded bracket is locked in place, push the recessed button to release it. Once released, you should feel some resistance from the spring as you slide the bracket up and down a few millimeters in each direction. STEP 3: STEP 4: Insert the top of the DIN-Rail into the...
  • Page 12: Grounding The Toughnet Switch

    ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or wiring your Moxa switch. This device has UL508 approval. Use copper conductors only, 60/75°C, and tighten to 4.5 pound-inches. For use in pollution degree 2 environments. Please read and follow these guidelines: Use separate paths to route wiring for power and devices.
  • Page 13: Connecting The Power Supplies

    Connecting the Power Supplies The ToughNet TN-5508/5510 switches support two sets of power supplies—power input 1 and power input 2.The M23 5-pin male connector on the TN-5508’s front panel is used for the dual power inputs. Use a power cord with an M23 5-pin female connector to connect the power inputs to the switch.
  • Page 14: Connecting The Relay Outputs

    ATTENTION Before connecting the TN-5508/5510 to the power input, make sure the power source voltage is stable. Connecting the Relay Outputs Each TN-5508/5510 switch has two sets of relay outputs—relay output 1 and relay output 2. The M12 A-coded 5-pin male connector on the TN-5508/5510’s front panel is used for the two relay outputs.
  • Page 15 Pinouts for the 10/100BaseT(X) Ports on the TN-5508/5510. Housing: shield Pinouts for the RJ45 (8-pin) Port RJ45 (8-Pin) MDI Port Pinouts MDI-X Port Pinouts Signal Signal Tx + Rx + Tx - Rx - Rx + Tx + Rx - Tx - M12 (4-pin, M) to M12 (4-pin, M) Cross-Over Cable Wiring Cross-Over Cable Wiring...
  • Page 16: 1000Baset Ethernet Port Connection

    M12 (4-pin, M) to RJ45 (8-pin) Straight-Trough Cable Wiring Straight-through Cable Wiring 10/100/1000BaseT(X) Ethernet Port Connection The TN-5510-2GTX models have two Gigabit Ethernet ports with RJ45-type circular connectors. The 10/100/1000BaseT(X) ports located on the bottom of the TN-5510 are used for connecting Ethernet-enabled devices.
  • Page 17 Rotary Switch IP Address Settings The ToughNet TN-5508/5510 switches have 3 rotary switches on the front panel for configuring the IP address without using a PC, making onsite configuration extremely convenient. This can be especially helpful when you need to replace a faulty switch quickly. STEP 1: Remove the protective cover by unscrewing the 2 screws with an Allen wrench (also called an Allen key or hex key).
  • Page 18: Led Indicators

    from Switch B to C will interconnect automatically; this way there is no stoppage. The bypass relay function helps the network recover from single-node failures in a linear topology. Switch A Switch B Switch C Switch D Bypassing With the maximum segment length of category 5 twisted-pair cable being 100 meters, cable length must be considered when designing a network that utilizes this function.
  • Page 19: Specifications

    When the TN switch is Ring Master of this Turbo Ring and the Turbo Ring is broken, or Blinking it is Chain Head of this Turbo Chain and the Turbo Chain is broken. When the TN switch is neither the Master of this Turbo Ring, nor the Head of this Turbo Chain.
  • Page 20 MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9 Flow Control IEEE802.3x flow control, back pressure flow control Switch Properties Priority Queues Max. Number of Available VLANs VLAN ID Range VID 1 to 4094 IGMP Groups Interface Fast Ethernet...
  • Page 21 Overload Current Present Protection Reverse Polarity Present Protection Physical Characteristics Housing Metal, IP54 protection (with protective caps on unused ports) Dimensions (W × H × D) TN-5508 Series: 185 x 170 x 69.8 mm (7.28 x 6.69 x 2.75 in) TN-5510 Series: 185 x 183 x 69.8 mm (7.28 x 7.20 x 2.75 in) Weight...
  • Page 22 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: +1-714-528-6777 Tel: +86-21-5258-9955 Fax: +1-714-528-6778 Fax: +86-10-6872-3958 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0 Tel: +886-2-8919-1230 Fax: +49-89-3 70 03 99-99 Fax: +886-2-8919-1231 —...

This manual is also suitable for:

Toughnet tn-5510 series

Table of Contents