Arctic Cat 2015 400 Service Manual page 95

Table of Contents

Advertisement

Voltage (Headlights)
 NOTE: Perform this test on the main harness side of
the connectors. Also, the ignition switch must be in
the LIGHTS position.
1. Set the meter selector to the DC Voltage position.
2. Connect the black tester lead to the black wire; then
connect the red tester lead to the white wire.
3. With the dimmer switch in the LO position, the
meter must show battery voltage.
4. Remove the red tester lead from the white wire and
connect to the lavender wire.
5. With the dimmer switch in the HI position, the meter
must show battery voltage.
 NOTE: If battery voltage is not shown in any test,
inspect the fuses, battery, main wiring harness, con-
nectors, or the left handlebar switch.
Voltage (Running Lights)
1. Release the wire connector from the frame; then
release and separate the connectors.
 NOTE: Perform this test on the wiring harness side
of the connectors.
2. Connect the black tester lead of the meter to the
black wire; then with the tester in the DC Volts posi-
tion, connect the red tester lead to the brown/black
wire.
3. Turn the ignition switch to the LIGHTS position.
The meter must show battery voltage.
 NOTE: If the meter does not show voltage, inspect
the LIGHTS fuse, battery connections, or trouble-
shoot the main wiring harness.
TAILLIGHTS - BRAKELIGHTS
Voltage (Taillights)
 NOTE: Perform this test on the main harness side of
the connector. Also, the ignition switch should be in
the LIGHTS position.
1. Set the meter selector to the DC Voltage position.
2. Connect the black tester lead to the black wire; then
connect the red tester lead to the brown/blue wire.
3. The meter must show battery voltage.
 NOTE: If the meter does not show voltage, inspect
fuses, wiring harness, connectors, and switches.
Voltage (Brakelights)
 NOTE: Perform this test on the main harness side of
the connector. Also, the ignition switch should be in
the ON position and the brake (either foot pedal or
hand lever) must be applied.
1. Set the meter selector to the DC Voltage position.
2. Connect the black tester lead to the black wire; then
KC223
connect the red tester lead to the green/yellow wire.
3. The meter must show battery voltage.
 NOTE: If the meter does not show voltage, inspect
bulb,
fuses,
switches.
BACK-UP LIGHTS
The connectors are located on the rear frame supports
attached by a metal tab. They may be released from the
frame by depressing the release with a small screwdriver.
Voltage
1. Release the wire connectors from the frame; then
disconnect the connectors.
 NOTE: Perform this test on the main harness side of
the connectors.
2. Connect the black tester lead to the brown/lavender
wire; then connect the red tester lead to the laven-
der/red wire.
wiring
harness,
connectors,
and
KC279
KC280