Table 5: System Alarm Option Definitions - Canoga Perkins EdgeAccess Universal Chassis System 2361 T1 User Manual

Table of Contents

Advertisement

The EdgeAccess Universal Chassis System
Alarm Name
Modem
Redundancy Status
Configuration
Errors
Fiber Loss of Signal
Electrical Loss of
Signal
Alarm Indication
Signal
Link Self Test
Status
SQL Primary
Optical Transmit
Level
SQL Secondary
Chassis
Management

Table 5: System Alarm Option Definitions

Condition
Reports the status of
the Remote and
Local, Primary and
Secondary Modems.
Fiber connection
error, remote partner
error, (see CFG LED
error list in section
3.1.1)
Composite (fiber)
loss of sync
Loss of signal to the
ELIM
Receiving AIS
The auxiliary BERT
(which is always
running) is out of
sync.
Indicates inadequate
signal quality through
fiber. A possible
indicator of poor
quality fiber.
Certain OLIMs allow
monitoring of
transmission power
(light level). Indicates
condition of optic
signal.
Indicates condition of
optic signal in
secondary
(redundant) OLIM.
Indicates presence of
an operative DMM
anywhere in the
domain (even in a
different chassis).
2361 Modem Users Manual
Notification
Active, Inactive and N/A
OS, OLIM type, OLIM slot, ELIM
type, ELIM slot, Fiber line Setup
(see the note at the bottom of this
table)
No, Yes
No, Yes
OK
OK, Bad, and NA (NA indicates
composite loss of sync)
OK, Bad
OK, Bad, or NA, if OLIM that
supports this feature is not present.
OK, Bad, NA
OK:
A functioning DMM is present
OFF: No DMM is present
BAD: The Proprietary Chassis Link,
or the DMM itself is not
functioning properly
LED
None
CFG
LOS
LOS
AIS
on
ELIM
TST
SQL
on
OLIM
4-11

Hide quick links:

Advertisement