The EdgeAccess Universal Chassis System
2. This screen reports the number of link errors for both the local and remote modems. Errors
counted here listed below:
Composite LOS Errors
Electrical LOS Errors
Electrical AIS Errors
SQL Primary Errors
Optical Transmit Errors
SQL Secondary Errors
Link Self Test Errors
Link Self Test LOS
To determine the number of errors, reset the errors to zero and allow errors to accumulate,
helping you determine which modem or link has a problem.
To reset the error counter, press Tab, then enter, as indicated on the screen.

5.3 Standalone Modem Diagnostic Tools

The 2361 rackmount modem has no panel switches for loopbacks. All loopback tests are
controlled via software. The standalone modem, however, does have a limited set of hardware-
controlled loopbacks that are on the front panel. On the front of the 2361 standalone modem, near
the right center, note the switch labeled loopback. It has three positions, Local, Off, and Remote.
Loc: Sets a loopback test on the local modem
Off: Loopback tests are off
Rem: Sets a loopback on the remote modem
The 2361 standalone modem also provides the same set of software-controlled loopback tests
available on the rackmount modem.
5-2

Figure 32. The Standalone 2361 Modem

2361 Modem Users Manual