Canoga Perkins EdgeAccess Universal Chassis System 2361 T1 User Manual page 40

Table of Contents

Advertisement

The EdgeAccess Universal Chassis System
Alarm Name
Alarm Relay Inputs
Power Supply
Primary
Power Supply
Secondary
The Configuration Error Line Notifications are interpreted as follows:
OS - active software version is different either at the local, local redundant, remote, or remote
redundant unit.
OLIM type - local and remote OLIM types are not compatible.
OLIM slot - a known invalid card is inserted in the OLIM slot.
ELIM type - local and local redundant ELIM types are not compatible for redundancy.
ELIM slot - a known invalid card is inserted in the ELIM slot.
Redundancy - the local and remote modems are not compatible for redundancy, one modem
is redundant and the other is not.
Fiber Line - fiber cable is not properly installed (i.e. cable is not properly connected from
local Tx connector to remote Rx connector, or cable is not properly connected (primary
connected to secondary instead of primary).
Setup - all the online modems have discrepancies on: modem rate, loopback control mode,
line coding, framing, or switch over mode.
4-12
Condition
On Standalone
modem only,
indicates presence of
Major and Minor
alarms
Indicates condition of
primary power supply
In rack unit, indicates
condition of
secondary power
supply, if available.
2361 Modem Users Manual
Notification
Major, Minor, None, and "Maj & Min"
OK:
Power supply is operative
BAD: Power supply is detected by
The CIM, and known to be
bad.
N/A: A CIM is not present, not
functioning correctly, or the
chassis backplane has a
problem.
OK:
Power supply is operative
BAD: Power supply is detected by
The CIM, and known to be
bad.
N/A: A CIM is not present, not
functioning correctly, or the
chassis backplane has a
problem.
LED

Hide quick links: