2.2.2.2 Internal Clock Option Switches

There are two switches on the Internal switch block which affect the operation of
the Clock circuits:
TBL / NORM
CLK / EXT

2.2.2.2.1 TBL / NORM Switch

The TBL / NORM switch controls the Data Rate Table as indicated in Table 3-D.
It is configured as ON when shipped from the factory. If it is switched to OFF,
the alternate Divide Ratios become active.
Factory Setting = ON

2.2.2.2.2 CLK / EXT Switch

The CLK / EXT switch controls which clock is used for synchronous input. If it is
switched to ON, any mode which sources Send Timing (Internal or Slave) will use
a turned-around clock coming in on Terminal Timing from the user's equipment.
This compensates for round-trip delays in the sourced clock which could other-
wise shift the clock-data phasing of the transmit signal and cause errors. This
setting can only be used where leads for both are available, and if the user's
equipment can turn the Send Timing back around onto the Terminal Timing leads,
either internally or at the other end of the cable.
NOTE: The ON setting of the CLK / EXT switch is required for
operating redundant modems using either internal or slave clocking.
Factory Setting = OFF
2240 Fiber Optic Modem