Setting Modem / Slip / Ppp Baud Rate Configuration; Specifying A Modem Initialization String; Resetting The Configuration To Default Values; Exporting Modem Configuration Settings - Canoga Perkins EdgeAccess Universal Chassis System 2361 T1 User Manual

Table of Contents

Advertisement

The EdgeAccess Universal Chassis System

4.3.3 Setting Modem / SLIP / PPP Baud Rate Configuration

To configure the communication port, use the Modem / SLIP / PPP Configuration Screen, and do
the following:
1. From the Main Menu, type "5" and press Enter. The Utilities screen will open.
2. Type "3". The Modem / SLIP / PPP Baud Rate Configuration Screen appears:
3. The current settings will be displayed. To change them, do the following:
Select 1 to chose Modem/ SLIP/ PPP Baud rate
Select 2 to type Modem Initialization String
Note: Applies only to standalone 2361 modem with SNMP option.

4.3.4 Specifying a Modem Initialization String

To change the modem initialization string from its default value, do the following:
1. From the Main Menu, type "5" and press Enter. The Utilities screen will open.
2. Type "4". A prompt appears for typing a new string, up to 20 characters
3. Type the string, and press enter to confirm.
Note: Applies only to standalone 2361 modem with SNMP option.

4.3.5 Resetting the Configuration to Default Values

If you have changed the major and minor alarm, switchover or redundancy mode settings, you
can reset to the factory defaults from the Utilities screen by performing the following:
1. From the Main Menu, type "5" and press Enter. The Utilities screen will open.
2. Type "5". A prompt to confirm restoring the default configuration will appear.
3. Press Enter to restore default values. The modem alarm and trap settings default will be
restored.
4. Copy configuration to other modems in the link. (See Exporting Modem Configuration
Settings section)

4.3.6 Exporting Modem Configuration Settings

To copy modem configuration settings (Switchover mode, Loopback control mode and Alarm
settings) to other modems in the links (primary and secondary, remote and local partners), do the
following:
1. From the Main Menu, type "5" and press Enter. The Utilities screen will open.
2. Type "7". You'll be prompted to select which modem to copy the configuration from. Your
choices will be Local Secondary, Remote Secondary, and Remote Primary (the current
modem is the Local Primary).
3. Press the space bar to specify which modem will send its configuration settings to all others
in the Chassis.
4. Press Enter to copy the configuration to the other modems.
2361 Modem Users Manual