The EdgeAccess Universal Chassis System
1. From the Main Menu, type "1"
and press Enter, to open the
System Configuration screen.
2. Type "4" to open the Alarm
Output Configuration screen.
3. The Alarm Output
Configuration screen appears.
There are nine configurable
alarm states, listed by number
(See Table 4).
4. To configure a particular alarm,
begin by typing its number in
the list and pressing Enter.
5. Use the space bar to toggle
through alarm choices: Major,
Minor or Off.
6. Press Enter to confirm the
alarm configuration choice.
4.4.4 Alarm Functions and Default Settings
The table below describes each alarm's function and its factory default setting.
Table 4: Alarm Output Configuration Option Definition
Alarm Name
1 Active Composite Link Alarm Enables or disables alarms 2 through 9
2 Electrical LOS
3 Electrical AIS Alarm
4 Configuration Alarm
5 Power Supply Alarm
6 Test Alarm
7 Link Self Test Alarm
8 Power On Self Test Alarm
9 Inactive Composite Link
Alarm
Figure 28. The Alarm Output Configuration Screen
Function
Loss of signal received from attached
equipment
"All 1's" signal pattern received from
attached equipment
Incompatibility between local and
remote modem, or between main
modem module and the LIMs attached
to it
Failure of power supply in the remote
chassis
Failure of Bit Error Rate Test (BERT) or
failure in the continuous self-test
operation
Failure of fiber between Local and
Remote units
Failure of Power-On self-test
In a redundant configuration, failure of
the redundant or inactive link
2361 Modem Users Manual
Default
Factory
Setting
Major
Major
Minor
OFF
Minor
OFF
Minor
Major
Minor
4-9