Check A New Installation; Alarms; Table 6. System Alarms Definitions - Canoga Perkins 2346 User Manual

T3 fiber optic modem
Table of Contents

Advertisement

The front panel LEDs show both normal and fault conditions. Typically, if a LED is steady red, the
fault is in the local 2346; if it blinks red, the fault is in the remote modem. Additional information
about fault conditions appears in the System Alarms and System Configuration screens. To aid
troubleshooting, Table 1 lists the functions of the front panel LEDs. For details on the LED status
during normal start-up and operation, see Chapter 2.
Additional information about fault conditions appears in the System Alarms, Hardware
Configuration, and Functional Configuration screens.

Check a New Installation

On new installations, make sure that all steps in Chapter 2 are complete, then make these checks:
The STA LED is green
The fiber type (multimode or single mode) matches the 2346 optical mode
All fiber cabling is of the same type; do not mix multimode and single mode cables
The fiber optic cable is within the specifications and loss budget of the optic interface module
The line length between the 2346 and the remote link does not exceed the allowable loss
budget or overdrive limit
All host modules in the link are turned on
All fiber cables are connected Tx to Rx and Rx to Tx

Alarms

The System Alarms screen reports alarms and faults on the 2346. To view current alarm status,
follow these steps:
1. From the Main Menu, type 3, Alarms, and press <Enter>. The System Alarms report appears.
2. To return to the Main Menu, press <Esc>.

Table 6. System Alarms Definitions

Item
Configuration Errors
Fiber/Electrical Loss of Signal
SQL Rx
Chassis Management
Alarm Relay Inputs
Power Supply Primary/Secondary Function of main/second power supply
Chassis Temperature
Fan
Power-On Self Test
EdgeAccess Universal Chassis System
If the local and remote modems have incompatible set ups,
including software version
If optical or electrical loss of signal occurs
If squelch occurs
OK if 2346 is in managed chassis or N/A if in standalone
Loss if CLS occurs or OK if signal is good; UCS 1001, only
Excessive temperature
Failure
OK or faulty hardware or software
2346 T3 Modem
Reports. . .
4-3