Chimney Inspection - Rinnai Timberflame IB35 ETR Operating And Installation Instructions

Table of Contents

Advertisement

CHECK DIMENSIONS OF FIREPLACE
Check dimensions of fireplace and if necessary
bring them to dimensions shown.
CHECK FLUEWAY
Check flueway is clear of obstructions.
Provide a firm, flat and sealed base for unit.
Sealed means no holes or openings in fireplace.
A rough base may affect the performance of this unit

CHIMNEY INSPECTION

A. Improper chimney height.
B. Chimney Cap deterioration.
C. Creosote stains.
D. Blockage within flue.
E. Clearance to combustibles.
F. Soot / Creosote accumulation.
G. Structural deterioration.
H. Loose or broken bricks.
I. Smoke Pellet test. (Leakage)
SEALING THE INBUILT
INSTALLATION
Peel protective backing off the foam strips supplied
with the heater. Attach strips to rear of casing as
shown.
The strip is intended to form a seal between the
heater and fireplace. If an adequate seal cannot be
formed with this strip, another means of sealing must
be used (eg. non-combustible insulation), between
the fireplace and the heater body.
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents