AT command
ATO
Returns to online data mode from
online command mode during
communication.
[M]
ATQ<n>
Sets whether to display result
codes.
*1
[M]
ATV<n>
Sets manner of displaying result
codes.
*1
[M]
ATX<n>
Sets whether to include speed in
the CONNECT display when
connecting. Also detects busy
tone or dial tone.
[M]
ATZ<n>
Resets the FOMA terminal's AT
command settings.
[M]
ATS0=<n>
Sets number of rings before
FOMA terminal automatically
receives.
[M]
ATS2=<n>
Sets the escape character.
[M]
ATS3=<n>
Sets the carriage return (CR)
character.
[M]
ATS4=<n>
Sets the line feed (LF) character.
[M]
Overview
*2
*1
*2, 4
*1
Parameter/Explanation
―
n=0 : Displays result codes (default setting)
n=1 : Does not display result codes
Displays all result codes with numbers or text.
n=0 : Displays result codes with numbers
n=1 : Displays result codes with text (default
setting)
Busy tone detection:
Sends BUSY response when number dialed
is busy.
Dial tone detection:
Determines whether FOMA terminal is
connected.
Speed display:
Sets whether to include speed in the
CONNECT display when connecting.
n=0 : No busy tone detection, no dial tone
detection, no speed display
n=1 : No busy tone detection, no dial tone
detection, speed display
n=2 : No busy tone detection, dial tone
detection, speed display
n=3 : Busy tone detection, no dial tone
detection, speed display
n=4 : Busy tone detection, dial tone detection,
speed display (default setting)
Resets the FOMA terminal's AT command
settings to the values set in non-volatile
memory. If this command is entered during
communication, the settings are reset after
disconnected.
Can only be set as n=0 (can be omitted)
n=0 : No automatic receiving (default setting)
n=1 to 255 : Automatically receives after sets
number of rings
n=0 to 127 (default setting: n=43)
When n=127 is set, escape is disabled.
Defines the character used to recognize the
end of an AT command character string.
Appended to the end of the echoed command
character string and result code. The settings
cannot be changed (default setting: n=13).
Appended after the CR character, when result
codes are displayed as text. The settings
cannot be changed (default setting: n=10).
36
Execution
example
ATOo
CONNECT
ATQ0o
OK
ATV1o
OK
ATX1o
OK
(When online)
ATZo
NO CARRIER
(When offline)
ATZo
OK
ATS0=0o
OK
ATS2=43o
OK
ATS2?o
043
OK
ATS3=13o
OK
ATS3?o
013
OK
ATS4=10o
OK
ATS4?o
010
OK
Need help?
Do you have a question about the SH-03E and is the answer not in the manual?