Disassembly Procedures
Water Valve Removal
1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Remove two screws each hot and 3 valve combo cold
valve.
Combo Cold Valve
4. Remove hose clamps and hoses.
NOTE: The hose circuitry is marked on the Dispenser
top.
Dispenser Removal
1. Disconnect power supply to unit.
2. Depress the release tab and slide drawer from
washer.
28
Downloaded from
www.Manualslib.com
!
WARNING
Hot Valve
manuals search engine
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
3. Remove Top Cover.
4. Remove clamps and hoses from dispenser.
Pre
Wash
NOTE: The hose circuitry is marked on the Dispenser
top.
5. Remove attachment screws and lift dipenser to
expose fill hose.
16026126 Rev. 0
Main
Main
Bleach
Cold
Hot
©2005 Maytag Services