identifying which drive has failed.
2.
Press <Ctrl-F> keys to enter FastBuild Main Menu.
3.
Select submenu Define Array <3>.
4.
Select the failed array and identify the Channel and ID of the failed drive.
5.
Power off and physically remove the failed drive.
6.
Replace the drive with an identical model.
7.
Reboot the system and enter the FastBuild Main Menu.
8.
Select the <5> Rebuild Array option. The following screen will appear.
FastBuild (tm) Utility 1.xx (c) 1995-2000 Promise Technology, Inc.
Array No
RAID Mode
Array 1
Mirror
Array 2
——
Array 3
——
Array 4
——
9.
Highlight the array whose Status is "Critical".
10. Press [Enter]. The following screen will then appear.
[ Rebuild Array Menu ]
Total Drv
2
——
——
——
[ Keys Available ]
[↑] Up [↓] Down
Capacity(MB)
16126
——
——
——
[ESC] Exit
[Enter] Select
117
Status
Critical
——
——
——