Programming The Locations For Nx-507E/Nx-508E - GE NX-10 Installation Manual

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

Location
Term
9.1.4
Users
9.1.4.1.1
Outputs
9.1.5
Model
9.1.6
Version
9.1.7
Reset Settings

Programming the locations for NX-507E/NX-508E

LOCATION 0 - PROGRAMMING THE EVENT, USER/ZONE AND TIME FOR OUTPUT 1 (3 segments,
numerical data)
Segment 1 - Event
Selects the event that will trigger the output. See chart below for the specific events that can be
selected.
Segment 2 - Zone/user
Selects the zone or user number necessary to trigger an output. If this location is programmed as a
zero ("0"), any zone or user will activate the output (see also location 68).
Segment 3 - Time
Selects the amount of time an output will remain activated when an output triggers. If this location is
programmed as a zero, the output will follow the particular event.
Nr.
Event
0**
Burglary alarm
1**
Fire alarm
2**
24 hour alarm
3**
Zone trouble (fire/day)
4**
Zone tamper
5
Burglary siren
6
Fire siren
7
Any siren
8
Zone bypass
9
AC failure
Definition
A menu option that specifies the zone or user number that
triggers the output on the expander module or power
module.
A menu option that specifies which outputs the selected
user can operate. The users menu can be used only when
event 45 (code entry) is used.
A menu option that displays the current model of the
selected output expander.
A menu option that displays the current software version of
the selected output expander.
A menu option that defaults the selected output expander.
Nr.
Event
21
Armed
22
Not armed
23
Ready
24
Not ready
25
Fire
26
Fire trouble
27
Chime
28**
Expander trouble
29
Dynamic battery
test
30**
Open schedule
Nr.
Event
42
Any zone faulted
43**
Any alarm
44
Keypad beeping
45**
Code entry
46♦
Key FOB function 1
47♦
Key FOB function 2
48♠
Auto arm control
49♠
Auto disarm control
50♠
Auto arm & disarm control
51
Follow schedule of NX-508E

Hide quick links:

Advertisement

Table of Contents
loading