seconds before activating the lock. Therefore, this option is to be set when controlling a
maglock or drop bolt. Loc.3, Seg.1 must be programmed for this option to work.
No Unlock Latch: This is used in conjunction with scheduling and controlling a door lock via the
relay output. If this option is NOT selected and scheduling is enabled then the door remains
unlocked after the first unlock within an open schedule and relocks upon closing. If this option
is selected, then the door does not remain unlocked, but follows the programmed relay driver
time.
Location 3 Programming the Zones (3 segments of numerical data)
Segment 1
Segment 2
Segment 3
When the starting zone number is set above the last zone of the system, the zone indication LEDs remain OFF.
Location 4 Programming the Various Reader Timers (4 segments of numerical data)
Segment 1
Segment 2
Segment 3
Segment 4
Location 5 Programming the Opening Time for Schedule 1 (2 segments of numerical data)
Segment 1
Segment 2
Door Shunt Zone. Program the zone that is monitored for sounding the Door Prop Alarm.
Program a 0 (default) to disable this function. See Location 4, Segment 3 for the length of
time the zone is monitored before sounding the alarm.
Request to Exit (RTE) Zone. Program the zone that is monitored to signal an RTE. If this
segment is programmed with a valid zone and the zone is faulted, the reader activates
its onboard relay driver and send the RTE. The RTE is not sent if Segment 2 contains an
invalid zone. (Default is 0.)
Starting zone number. Enter the systems starting zone number for this ProxPad. Default
value is 1 which sets it to show the zone status of up to the first 8 zones of the partition
to which this ProxPad is programmed. The starting zone can be any zone number within
the range of the control panel.
Scan Time. Enter the time required for a double badge or triple badge function to be
detected to activate the functions programmed in Location 0, Segments 2 and 3. This
timer is set in 1/100 second increments from 0 to 2.55 seconds. (Default is 100 = 1
second).
Relay Active Time. Enter the amount of time the Relay is energized once activated. This
timer is set in 1/10 second increments from 0 to 25.5 seconds. (Default is 10 = 10
seconds).
Door Fault Warning Time. Enter the amount of time a monitored zone (see Location 3,
segment 1) must be faulted before sounding an alarm (local buzzer). This timer is timed
in 1 second increments from 0 to 255 seconds. (Default is 30 = 30 seconds).
Door Fault Alarm Time. Enter the amount of time a monitored zone (see Location 3,
segment 1) must be faulted before sending an alarm condition to the control panel. The
door fault alarm is set in 1 second increments from 0 to 255 seconds. (Default is 60 = 60
seconds.)
Program the hour of the opening time in 24-hour format. (Default is 8 = 8:00 AM)
Program the minutes after the hour of the opening time for Schedule 1. (Default is 0.)
NX-10 Expander Installation Guide
55