needs to be programmed if Location 0, Segment 2, Option 7 is set. Use the above table. Default is 3.
Segment 5 Single Scan Hold Function (Triple Beep)
Program the X-10 function that is performed when a card is scanned and held at the reader for the
duration of the 2 Scan Hold Time {three beeps}. Location 244, Segment 1 programs the length of
time between beeps. The descriptions of the function codes are the same as for Single Beep Scan
Function. This location only needs to be programmed if Location 0, Segment 3, Option 7 is set. Use
the above table. Default is 2.
LOCATION 242 Programming the Options and Reader Partition (4 segments of binary data)
Segment 1 System options:
"On" if reader is enabled for User Card Programming.
1.
"On" if optical tamper is enabled.
2.
"On" if reader buzzer is to follow typical keypad buzzing. (Default is "On")
3.
"On" if ding-dong chime enabled (dependent on both Option 3 and chime being enabled).
4.
"On" if an RTE from a scanned card is to be logged as Code Entry. (Default is "On")
5.
"On" if reader is in NX-1701E Legacy Mode (Default is "On") Refer to note below.
6.
"On" if an RTE from a zone or the Egress input is to be logged as Code Entry.
7.
"On" if LEDs to extinguish after 2 minutes without a scan.
8.
Note: This option doesn't disable the flashing green LED during card programming.
Segment 2 LED1 (Green) options:
"On" to follow Ready status of system. (Default is "On")
1.
"On" to toggle with the open collector output activation. (Default is "On").
2.
"On" if inverted.
3.
Reserved.
4.
Reserved.
5.
Reserved.
6.
Reserved.
7.
Reserved.
8.
Segment 3 LED2 (Red) options:
"On" to follow Armed status of system. (Default is "On")
1.
"On" to toggle with the open collector output activation.
2.
"On" if inverted.
3.
Reserved.
4.