Clean the reinforcement knives

Clean the reinforcement knives
Introduction
The knives of the reinforcement unit get sticky from the glue on the reinforcement tape. You must
clean the knives regularly. If you clean the reinforcement knives, you must put the knives in such
a position that you have access to all the parts.
You are recommended to clean the knives when:
• You install a new tape roll
• When an error in the reinforcement unit has occurred.
IMPORTANT
Use only the original Cleaner K and Fixing Unit Cleaning Oil (silicon oil) from Océ to prevent
damage to the reinforcement unit.
Procedure
1.
Press the "Online" key on the printer operator panel to put the printer offline.
2.
Select "Folding" with the left selection key.
3.
Press the down key to enter the "Folding" menu.
4.
Select "Clean knife" with the left or right key.
NOTE
When a job is running, the message "Job interrupted" appears. The machine stops running after
it has correctly finished the prints that were already printing. The focus can now be set to the
Folding menu. A picture of the printer appears on the display with the side door of the
reinforcement unit blinking.
5.
Press the down key to put the reinforcement unit knives in the correct position.
6.
Open the side door of the reinforcement unit.
7.
Clean the upper and lower knife using Cleaner K.
[135] Cleaning the upper and lower knife
8.
Use the Fixing Unit Cleaning Oil (silicon oil) to oil the felt.
278
Chapter 7 - Maintain and troubleshoot the Océ PlotWave 750 system
Insert a new tape roll on page 272
or